Evaluation of an ultrasonic echo-tracking method for measurements of arterial wall movements in two dimensions

Cinthio, M. (author)
Department of Electrical Measurements, Lund University, 221 00 Lund, Sweden
Ahlgren, A.R. (author)
Department of Clinical Physiology, Lund University, Malmö University Hospital, 205 02 Malmö, Sweden, Department of Clinical Physiology, Lund University, Malmö University Hospital, Sweden
Jansson, Tomas (author)
Department of Electrical Measurements, Lund University
show more...
Eriksson, A. (author)
Department of Electrical Measurements, Lund University, 221 00 Lund, Sweden, Naval Underwater Technology, Kockums, Alta.
Persson, H.W. (author)
Department of Electrical Measurements, Lund University, 221 00 Lund, Sweden, Lund Institute of Technology, Department of Electrical
Lindstrom, K. (author)
Department of Electrical Measurements, Lund University, 221 00 Lund, Sweden, Lund Institute of Technology, Lund University, Department of Radiology and Physiology, Malmö University Hospital
show less...
 (creator_code:org_t)
2005
2005
English.
In: IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control. - 0885-3010 .- 1525-8955. ; 52:8, s. 1300-1311
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • The longitudinal movement of blood vessel walls has so far gained little or no attention, as it has been presumed that these movements are of a negligible magnitude. However, modern high-resolution ultrasound scanners can demonstrate that the inner layers of the arterial wall exhibit considerable movements in the longitudinal direction. This paper evaluates a new, noninvasive, echo-tracking technique, which simultaneously can track both the radial and the longitudinal movements of the arterial wall with high resolution in vivo. Initially, the method is evaluated in vitro using a specially designed ultrasound phantom, which is attached to and moved by an X-Y system, the movement of which was compared with two high-resolution triangulation lasers. The results show an inaccuracy of 2.5% full scale deflection (fsd), reproducibility of 12 µm and a resolution of 5 µm, which should be more than sufficient for in vivo studies. The ability of the method is also demonstrated in a limited in vivo study in which a preselected part of the inner vessel wall of the right common carotid artery of a healthy volunteer is tracked in two dimensions over many cardiac cycles. The results show well reproducible x-y movement loops in which the recorded radial and longitudinal movements both are of the magnitude millimetre. © 2005 IEEE.

Keyword

TECHNOLOGY
TEKNIKVETENSKAP

Publication and Content Type

ref (subject category)