SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-56402"
 

Sökning: id:"swepub:oai:DiVA.org:liu-56402" > A Monte Carlo-based...

  • Ullman, GustafLinköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiofysik,Hälsouniversitetet (författare)

A Monte Carlo-based model for simulation of digital chest tomosynthesis

  • Artikel/kapitelEngelska2010

Förlag, utgivningsår, omfång ...

  • 2010-03-04
  • Oxford :Oxford University Press,2010
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-56402
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-56402URI
  • https://doi.org/10.1093/rpd/ncq079DOI
  • https://gup.ub.gu.se/publication/117578URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • This is a pre-copy-editing, author-produced PDF of an article accepted for publication in Radiation Protection Dosimetry following peer review. The definitive publisher-authenticated version: Gustaf Ullman, David R. Dance, Michael Sandborg, Gudrun Alm Carlsson, Angelica Svalkvist and Magnus Båth, A MONTE CARLO-BASED MODEL FOR SIMULATION OF DIGITAL CHEST TOMOSYNTHESIS, 2010, Radiation Protection Dosimetry, (139), 1-3, 159-163. is available online at: http://dx.doi.org/10.1093/rpd/ncq079 Copyright: Oxford University Press http://www.oxfordjournals.org/
  • The aim of this work was to calculate synthetic digital chest tomosynthesis projections using a computer simulation model based on the Monte Carlo method. An anthropomorphic chest phantom was scanned in a computed tomography scanner, segmented and included in the computer model to allow for simulation of realistic high-resolution X-ray images. The input parameters to the model were adapted to correspond to the VolumeRAD chest tomosynthesis system from GE Healthcare. Sixty tomosynthesis projections were calculated with projection angles ranging from +15 to −15°. The images from primary photons were calculated using an analytical model of the anti-scatter grid and a pre-calculated detector response function. The contributions from scattered photons were calculated using an in-house Monte Carlo-based model employing a number of variance reduction techniques such as the collision density estimator. Tomographic section images were reconstructed by transferring the simulated projections into the VolumeRAD system. The reconstruction was performed for three types of images using: (i) noise-free primary projections, (ii) primary projections including contributions from scattered photons and (iii) projections as in (ii) with added correlated noise. The simulated section images were compared with corresponding section images from projections taken with the real, anthropomorphic phantom from which the digital voxel phantom was originally created. The present article describes a work in progress aiming towards developing a model intended for optimisation of chest tomosynthesis, allowing for simulation of both existing and future chest tomosynthesis systems.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Dance, David R.Royal Surrey County Hospital, Guildford (författare)
  • Sandborg, MichaelÖstergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiofysik,Hälsouniversitetet,Radiofysikavdelningen(Swepub:liu)micsa02 (författare)
  • Alm Carlsson, GudrunÖstergötlands Läns Landsting,Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Medicinsk radiofysik,Hälsouniversitetet,Radiofysikavdelningen(Swepub:liu)gudal03 (författare)
  • Svalkvist, AngelicaGothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,University of Gothenburg(Swepub:gu)xsvala (författare)
  • Båth, Magnus,1974Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för radiofysik,Institute of Clinical Sciences, Department of Radiation Physics,University of Gothenburg(Swepub:gu)xbatma (författare)
  • Linköpings universitetCentrum för medicinsk bildvetenskap och visualisering, CMIV (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Radiation Protection DosimetryOxford : Oxford University Press139:1-3, s. 159-1630144-84201742-3406

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy