SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Dance David R.)
 

Search: WFRF:(Dance David R.) > (1995-1999) > Implementation of u...

Implementation of unsharpness and noise into the model of the imaging system : Applications to chest and lumbar spine screen-film radiography

Sandborg, Michael (author)
Östergötlands Läns Landsting,Linköpings universitet,Radiofysik,Hälsouniversitetet,Radiofysikavdelningen
Dance, David R (author)
Joint Department of Physics, The Royal Marsden NHS Trust, UK
Alm Carlsson, Gudrun (author)
Östergötlands Läns Landsting,Linköpings universitet,Radiofysik,Hälsouniversitetet,Radiofysikavdelningen
 (creator_code:org_t)
Linköping : Linköping University Electronic Press, 1999
English 50 s.
Series: Report / Institutionen för radiofysik, Universitetet i Linköping, 1998- ; 90
  • Reports (other academic/artistic)
Abstract Subject headings
Close  
  • A model of the complete x-ray imaging system including the patient is a powerful tool for imaging system analysis and the optimisation of image quality and patient dose. It allows flexible variation of the system components (i.e. x-ray source, antiscatter device and image detector) and study of their effect on image quality and patient risk. Our group has developed, validated and calibrated a Monte Carlo model of the complete imaging system for chest and lumbar spine examination including voxalised human male anatomy. The Monte Carlo program calculates the contrast and signal-to-noise ratio (SNR) of various contrasting details within the voxel phantom. Important details in the images have been selected by consulting radiologist and the EU document of image quality criteria. The entrance surface dose without back-scatter and the effective dose are used as measures of patient radiation risk. The contrasts of the details are derived initially from Monte Carlo estimates of the energy imparted per unit area to the image detector beside and behind the detail. However, this ignores the effects of unsharpness in the imaging chain (such as screen-film, geometric and motion unsharpness) and the influence on contrast of the film characteristic curve. In the Monte Carlo program, SNR is calculated assuming that the noise arises from the random fluctuations in the energy imparted per unit area to the image detector only. However, other noise sources also contribute to the total noise, such as screen and film noise. Hence the model of the imaging system needs to be further developed to take these effects into account. The methods used to extend the model are described below together with illustrations of their effect on the difference in optical density, DOD, and SNR in chest and lumbar spine imaging.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Radiological physics
Radiofysik

Publication and Content Type

vet (subject category)
rap (subject category)

To the university's database

Find more in SwePub

By the author/editor
Sandborg, Michae ...
Dance, David R
Alm Carlsson, Gu ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Parts in the series
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view