Comparison of clinical and physical measures of image quality in chest PA and pelvis AP views at varying tube voltages

Ullman, Gustav (author)
Linköpings universitet,Radiofysik,Hälsouniversitetet
Sandborg, Michael (author)
Östergötlands Läns Landsting,Linköpings universitet,Radiofysik,Hälsouniversitetet,Radiofysikavdelningen
Tingberg, Anders (author)
Department of Radiation Physics, Malmö University Hospital, Sweden
show more...
Dance, David R (author)
Department of Physics, The Royal Marsden NHS Trust, UK
Hunt, Roger (author)
Department of Physics, The Royal Marsden NHS Trust, UK
Alm Carlsson, Gudrun (author)
Östergötlands Läns Landsting,Linköpings universitet,Radiofysik,Hälsouniversitetet,Radiofysikavdelningen
show less...
 (creator_code:org_t)
Linköping : Linköping University Electronic Press, 2004
English 11 s.
Series: Report / Institutionen för radiofysik, Universitetet i Linköping, 1998- ; 98
  • Reports (other academic/artistic)
Abstract Subject headings
Close  
  • Image quality in digital chest PA and pelvis AP was assessed using two different methods; one based on observations of images of an anthropomorphic phantom, one based on computer modelling using an anthropomorphic voxel phantom. The tube voltage was varied within a broad range (50-150 kV), including those values typically used with screen-film radiography. The tube charge was altered so that approximately the same effective dose was achieved in the modelled patient (anthropomorphic phantom). Two x-ray units were employed using a digital image detector (computed radiography, CR, system) with standard tube filtration and anti-scatter device. Clinical image quality was assessed by a group of radiologists using a visual grading analysis (VGA) technique based on the revised CEC image criteria. Physical image quality was derived from the computer model in terms of the signal-to-noise ratio, SNR for fixed effective dose in the voxel phantom. The computer model uses Monte Carlo simulations of the patient and complete imaging system. Both the VGAS (visual grading analysis score) and SNR increase with decreasing tube voltage in both chest PA and pelvis AP examinations, indicating superior performance if lower tube voltages than used today are employed in digital radiology. A positive correlation between clinical and physical measures of image quality was found. The pros and cons of using lower tube voltages with CR digital radiography than typically used in analogue screen-film radiography are discussed as well as the relevance of using VGAS and quantum noise SNR as measures of image quality.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

image quality
effective dose
tube voltage
visual grading analysis
signal-to-noise ratio
chest radiography
pelvis radiography
computed radiography
Radiological physics
Radiofysik

Publication and Content Type

vet (subject category)
rap (subject category)

To the university's database

Find more in SwePub

By the author/editor
Ullman, Gustav
Sandborg, Michae ...
Tingberg, Anders
Dance, David R
Hunt, Roger
Alm Carlsson, Gu ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Radiology Nuclea ...
Parts in the series
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view