SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Ullman Gustav)
 

Search: WFRF:(Ullman Gustav) > On the extent of qu...

On the extent of quantum noise limitation in digital chest radiography

Ullman, Gustav (author)
Linköpings universitet,Radiofysik,Hälsouniversitetet
Sandborg, Michael (author)
Östergötlands Läns Landsting,Linköpings universitet,Radiofysik,Hälsouniversitetet,Radiofysikavdelningen
Dance, David R (author)
Department of Physics, The Royal Marsden NHS Trust, UK
show more...
Båth, M. (author)
Department of Radiation Physics, Göteborg, Sweden
Håkansson, M. (author)
Department of Radiation Physics, Göteborg, Sweden
Börjesson, S. (author)
Department of Radiation Physics, Göteborg, Sweden
Hunt, Roger (author)
Department of Physics, The Royal Marsden NHS Trust, UK
Alm Carlsson, Gudrun (author)
Östergötlands Läns Landsting,Linköpings universitet,Radiofysik,Hälsouniversitetet,Radiofysikavdelningen
show less...
 (creator_code:org_t)
Linköping : Linköping University Electronic Press, 2004
English 10 s.
Series: Report / Institutionen för radiofysik, Universitetet i Linköping, 1998- ; 98
  • Reports (other academic/artistic)
Abstract Subject headings
Close  
  • The aim for this work was to study to what extent the detection of nodules is quantum noise limited, based on the combined results from a nodule-detection clinical trial and a Monte Carlo computational model of a digital chest imaging system. The Monte Carlo computer program computes measures of physical image quality such as image contrast, C and signalto-noise ratio, SNR for nodules of any size. A computed radiography (CR) imaging system used simulated. The patient anterior-posterior thickness was 25 cm and nodules with diameters between 1-40 mm were included. The image contrast and SNR was calculated for 1600 (40x40) positions in the chest image and averaged over five anatomical regions of interest (lateral pulmonary, retrocardial, hilar, lower- and upper mediastinal regions). Threshold contrasts for each region, Cth, corresponding to Az=0.80 for detecting a 10 mm nodule, were deduced from the clinical trial. A threshold is also used for the quantum noise signal-to-noise ratio, SNRth. The model computes the diameter of a disk-shaped object that is required to comply with the two criteria: SNR≥SNRth and C≥Cth. A system is said to be quantum noise limited when the nodule size required to fulfil both criteria is not limited by the contrast but by the SNR. The required nodule diameter is largest in the hilar region (25 mm) and smallest in the lateral pulmonary region (11 mm). When the threshold SNRth=25 is used, the lower mediastinal region is quantum noise limited already at low speed classes (S>100). The hilar region is never quantum noise limited at realistic speed classes (S<1000). The accuracy of this model will be tested in the future by more sophisticated modelling of anatomical background and noise in the SNR-expression.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Keyword

Radiological physics
Radiofysik

Publication and Content Type

vet (subject category)
rap (subject category)

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view