SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Karin M)
 

Search: WFRF:(Karin M) > (1990-1994) > Spatial heterogeity...

Spatial heterogeity in normal skin perfusion recorded with laser Doppler imaging and flowmetry

Wårdell, Karin (author)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan
Braverman, I.M. (author)
Silverman, D.G. (author)
show more...
Nilsson, Gert (author)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan
show less...
 (creator_code:org_t)
1994
1994
English.
In: Microvascular Research. - 0026-2862 .- 1095-9319. ; 48:1, s. 26-38
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Spatial and temporal variations in forearm skin perfusion captured by laser Doppler perfusion imaging (LDI) have been compared with topographic maps recorded by laser Doppler flowmetry. In order to determine the shortest LDI sampling time required at each measurement site, with an adequate signal-to-noise ratio and with the ability to display the heterogeneity in skin perfusion, the noise-limited resolution of the LDI system as well as various sampling times were tested. The noise-limited resolution for medium and high light intensities were less than 0.5% (temporal) and 0.3% (spatial) of full scale. A sampling time of 1 sec was selected and image presentation was made by performing bilinear interpolation between perfusion values. The same area (10 x 10 mm) was mapped with LDI and topographic mapping at seven different sites. In addition, a larger area covering the surrounding skin was recorded with LDI. The small area recordings with LDI and topographic mapping could be identified in the larger LDI image. High-and low-perfusion spots coincided between the two systems. Temporal variations were studied by repeated LDI recordings of the same areas as above. Small spots were selected in the areas and plotted versus time. Without provocation, the total perfusion changes at each spot showed large variations, but the relative perfusion levels between neighboring spots persisted. Provocation with heat increased the perfusion in all spots.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Keyword

Medical engineering
Medicinsk teknik

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Wårdell, Karin
Braverman, I.M.
Silverman, D.G.
Nilsson, Gert
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Medical Laborato ...
Articles in the publication
Microvascular Re ...
By the university
Linköping University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view