SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(TURNER APF)
 

Sökning: WFRF:(TURNER APF) > (2000-2004) > Towards the develop...

Towards the development of an integrated capillary electrophoresis optical biosensor

Bossi, A (författare)
University Verona, Department Science and Technology, I-37134 Verona, Italy; Cranfield University, Institute Biosci and Technology, Silsoe, Beds, England;
Castelletti, L (författare)
University Verona, Department Science and Technology, I-37134 Verona, Italy; Cranfield University, Institute Biosci and Technology, Silsoe, Beds, England;
Piletsky, SA (författare)
University Verona, Department Science and Technology, I-37134 Verona, Italy; Cranfield University, Institute Biosci and Technology, Silsoe, Beds, England;
visa fler...
Turner, APF (författare)
Cranfield University, UK
Righetti, PG (författare)
University Verona, Department Science and Technology, I-37134 Verona, Italy; Cranfield University, Institute Biosci and Technology, Silsoe, Beds, England;
visa färre...
 (creator_code:org_t)
John Wiley andamp;amp; Sons, Ltd, 2003
2003
Engelska.
Ingår i: Electrophoresis. - : John Wiley andamp;amp; Sons, Ltd. - 0173-0835 .- 1522-2683. ; 24:19-20, s. 3356-3363
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Extending the previous preliminary study on the construction of a capillary electrophoresis (CE)/sensor for the detection of reducing analytes, we focus the interest on the simultaneous detection of redox active species, which are important indicators of the oxidative damage in tissues, of food preservation, and of pollution. The CE/sensor was built by modifying the detector-portion of the capillary with the redox-sensitive polymer polyaniline (PANI). The analyte is detected by monitoring the changes in optical absorption of the PANI film. The CE/sensor was tested, with good results, with ascorbic acid, glutathione (GSH), as well as with compounds with very close similarity (ascorbic and isoascorbic acid). The kinetics of oxidation and reduction of PANI were evaluated. Further a PANI/CE-biological sensor was developed by coupling an enzyme, glucose oxidase (GOD), to the PANI-modified portion of the capillary. The stability of the immobilized GOD and the sensitivity of the CE/biosensor were studied, by using glucose as test analyte in concentrations within the physiological range. The results indicate that the CE/biosensor had good stability (more than 75% of original activity retained after 30 operational days), manufacturing reproducibility and a sensing range convenient for monitoring physiological glucose (1-24 mm).

Nyckelord

biosensor; capillary electrophoresis; chemical sensor; glucose oxidase; redox analytes
TECHNOLOGY
TEKNIKVETENSKAP

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy