Development of an integrated capillary electrophoresis/sensor for L-ascorbic acid detection

Castelletti, L (författare)
University Verona, Department Science and Technology, I-37134 Verona, Italy; Cranfield University, Institute Biosci and Technology, Silsoe, Beds, England;
Piletsky, SA (författare)
University Verona, Department Science and Technology, I-37134 Verona, Italy; Cranfield University, Institute Biosci and Technology, Silsoe, Beds, England;
Turner, APF (författare)
Cranfield University, UK
visa fler...
Righetti, PG (författare)
University Verona, Department Science and Technology, I-37134 Verona, Italy; Cranfield University, Institute Biosci and Technology, Silsoe, Beds, England;
Bossi, A (författare)
University Verona, Department Science and Technology, I-37134 Verona, Italy; Cranfield University, Institute Biosci and Technology, Silsoe, Beds, England;
visa färre...
 (creator_code:org_t)
John Wiley andamp;amp; Sons, Ltd, 2002
2002
Engelska.
Ingår i: Electrophoresis. - : John Wiley andamp;amp; Sons, Ltd. - 0173-0835 .- 1522-2683. ; 23:2, s. 209-214
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • A CE/biosensor for measuring ascorbic acid was developed by coupling a polyaniline optical sensor and capillary electrophoresis (CE). The capillary column was partially modified with a thin film of polyaniline redox sensitive material. Ascorbic acid was detected by monitoring the changes in optical absorbance occurring to the polyaniline film upon the reduction reaction. The sensor response (change in optical absorbance at 650 nm) is proportional to the concentration of ascorbic acid over a range of 2.5-250 mg/L and the response range has shown a clear dependence on the characteristics of the polymerized film. High specificity and sensitivity of the present method, low sample consumption, short times of response (ca. 2 min) and the reproducibility of the results demonstrate that the CE/polyaniline-sensor could be further employed in the study of the relation between the content of L-ascorbic acid in body fluids and clinical parameters, e.g., cell ageing.

Nyckelord

capillary electrophoresis; sensor; polyaniline; ascorbic acid; antioxidants
TECHNOLOGY
TEKNIKVETENSKAP

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy