SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0956 5663 OR L773:1873 4235
 

Sökning: L773:0956 5663 OR L773:1873 4235 > (1995-1999) > AMPEROMETRIC DETECT...

AMPEROMETRIC DETECTION OF HISTAMINE AT A QUINOPROTEIN DEHYDROGENASE ENZYME ELECTRODE

LOUGHRAN, MG (författare)
CRANFIELD UNIV,CRANFIELD BIOTECHNOL CTR,CRANFIELD MK43 0AL,BEDS,ENGLAND; UNIV MISSISSIPPI,MED CTR,DEPT BIOCHEM,JACKSON,MS 39216;
HALL, JM (författare)
CRANFIELD UNIV,CRANFIELD BIOTECHNOL CTR,CRANFIELD MK43 0AL,BEDS,ENGLAND; UNIV MISSISSIPPI,MED CTR,DEPT BIOCHEM,JACKSON,MS 39216;
TURNER, APF (författare)
Cranfield University, UK
visa fler...
DAVIDSON, VL (författare)
CRANFIELD UNIV,CRANFIELD BIOTECHNOL CTR,CRANFIELD MK43 0AL,BEDS,ENGLAND; UNIV MISSISSIPPI,MED CTR,DEPT BIOCHEM,JACKSON,MS 39216;
visa färre...
 (creator_code:org_t)
Elsevier Science B.V., Amsterdam. 1995
1995
Engelska.
Ingår i: Biosensors & bioelectronics. - : Elsevier Science B.V., Amsterdam.. - 0956-5663 .- 1873-4235. ; 10:07-jun, s. 569-576
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Methylamine dehydrogenase, a tryptophan tryptophyl quinone (TTQ) containing quinoprotein, catalyzes the oxidation of a variety of primary aliphatic monoamines and diamines to their respective aldehydes and ammonia. This paper reports the construction and characterization of an enzyme electrode capable of detecting histamine and methylamine at +200 mV versus a saturated calomel reference electrode. The methylamine dehydrogenase isolated from Paracoccus denitrificans was used in conjunction with the insoluble mediator tetracyanoquinodimethane (TCNQ) to construct enzyme electrodes which will potentially provide simple rapid analysis of histamine without the need for the extensive sample pretreatments currently required in HPLC and GLC analysis. The linear response of this amperometric sensor, between 0 and 200 mu M, correlates well with elevated histamine levels predominant in patients with chronic myelogenous leukaemia, whilst the observed limit of detection, 4.8 mu M, compares favourably with the lower limits of detection reported for a potentiometric histamine sensitive enzyme electrode.

Nyckelord

QUINOPROTEIN; TRYPTOPHAN TRYPTOPHYL QUINONE; TTQ; METHYLAMINE DEHYDROGENASE; ENZYME ELECTRODE; TETRACYANOQUINODIMETHANE; TCNQ; HISTAMINE
TECHNOLOGY
TEKNIKVETENSKAP

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
LOUGHRAN, MG
HALL, JM
TURNER, APF
DAVIDSON, VL
Artiklar i publikationen
Biosensors & bio ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy