SwePub
Sök i LIBRIS databas

  Utökad sökning

AMNE:(ENGINEERING AND TECHNOLOGY Medical Engineering Medical Laboratory and Measurements Technologies)
 

Sökning: AMNE:(ENGINEERING AND TECHNOLOGY Medical Engineering Medical Laboratory and Measurements Technologies) > (1995-1999) > Motion compensated ...

Motion compensated digital subtraction angiography

Hemmendorff, M. (författare)
Linköpings universitet,Institutionen för systemteknik,Tekniska högskolan,SECTRA, Teknikringen 2, SE-583 30 Linköping, Sweden
Knutsson, Hans (författare)
Linköpings universitet,Medicinsk informatik,Tekniska högskolan,Bildbehandling
Andersson, Mats (författare)
Linköpings universitet,Medicinsk informatik,Tekniska högskolan,Bildbehandling
visa fler...
Kronander, T. (författare)
SECTRA, Teknikringen 2, SE-583 30 Linköping, Sweden
visa färre...
 (creator_code:org_t)
1999
1999
Engelska.
Ingår i: Proceedings of SPIE's International Symposium on Medical Imaging, vol 3661,  1999.
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Digital subtraction angiography, whether based on traditional X-ray or MR, suers from patient motion artifacts. Until now, the usual remedy is to pixel shift by hand, or in some cases performing a global pixel shift semi-automatically. This is time consuming, and cannot handle rotations or local varying deformations over the image. We have developed a fully automatic algorithm that provides for motion compensation in the presence of large local deformations. Our motion compensation is very accurate for ordinary motions, including large rotations and deformations. It does not matter if the motions are irregular over time. For most images, it takes about a second per image to get adequate accuracy. The method is based on using the phase from lter banks of quadrature lters tuned in dierent directions and frequencies. Unlike traditional methods for optical ow and correlation, our method is more accurate and less susceptible to disturbing changes in the image, e.g. a moving contrast bolus. The implications for common practice are that radiologists' time can be significantly reduced in ordinary peripheral angiographies and that the number of retakes due to large or local motion artifacts will be much reduced.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

Motion Compensation
Motion Estimation
Digital Subtraction Angiography
Aperture Problem
Pixelshift
Automatic
Quadrature Filter
Regularization
Medical engineering
Medicinsk teknik
TECHNOLOGY

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Hemmendorff, M.
Knutsson, Hans
Andersson, Mats
Kronander, T.
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk labora ...
Artiklar i publikationen
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy