Myocardial perfusion abnormalities by intravenous administration of the contrast agent NC100100 in an experimental model of coronary artery occlusion and reperfusion

Rovai, Daniele (författare)
CNR, Institute of Clinical Physiology, Pisa, Italy
Janerot-Sjöberg, Birgitta (författare)
Östergötlands Läns Landsting,Linköpings universitet,Fysiologisk mätteknik,Tekniska högskolan,Fysiologiska kliniken US
Nagy, András (författare)
Gottsegen György Hungarian Institute of Cardiology, Budapest, Hungary
visa fler...
Marini, Cecilia (författare)
CNR, Institute of Clinical Physiology, Pisa, Italy
Burchielli, Silvia (författare)
CNR, Institute of Clinical Physiology, Pisa, Italy
Castellari, Michele (författare)
CNR, Institute of Clinical Physiology, Pisa, Italy
Morales, Maria-Aurora (författare)
CNR, Institute of Clinical Physiology, Pisa, Italy
Trivella, M. Giovanna (författare)
CNR, Institute of Clinical Physiology, Pisa, Italy
Ostensen, Jonny (författare)
Nycomed Imaging AS, Oslo, Norway
Distante, Allessandro (författare)
University of Pisa, Pisa, Italy
L'Abbate, Antonio (författare)
CNR, Institute of Clinical Physiology, Pisa, Italy
visa färre...
 (creator_code:org_t)
Wiley, 1998
1998
Engelska.
Ingår i: Echocardiography. - : Wiley. - 0742-2822 .- 1540-8175. ; 15:8, s. 731-740
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of this study was to evaluate a second-generation echo contrast agent (NC100100) for the study of myocardial perfusion. In eight anesthetized open-chest dogs, this agent was injected intravenously under baseline conditions, during acute coronary thrombosis, and after reperfusion, using both fundamental (FI) and harmonic (HI) imaging, both continuous and intermittent imaging, and both ultrasound (US) and integrated backscatter (IBS) imaging. Contrast injections did not modify the hemodynamic parameters. With all imaging modalities, myocardial contrast enhancement (MCE) was higher with intermittent than with continuous imaging (134 vs 82 gray level/pixel using FI, P = 0.02; 62 vs 32 acoustic units using US HI, P = 0.02; and 52 vs 12 dB using IBS, P = 0.05). MCE equally increased using either US or IBS imaging. The accuracy of MCE in detecting perfusion defects during coronary occlusion and myocardial reperfusion after thrombolysis was very good (sensitivity and specificity = 93% and 95% and 89% and 93%, respectively). The extent of myocardial perfusion defects by echo contrast showed a closer correlation with microspheres using HI (r = 0.82) than FI (r = 0.53). Thus, the intravenous administration of NC100100 during intermittent HI allows myocardial perfusion abnormalities to be accurately detected during acute myocardial infarction.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

Medical engineering
Medicinsk teknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy