SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1872 4973 OR L773:1878 0326
 

Sökning: L773:1872 4973 OR L773:1878 0326 > (2010-2014) > Swedish population ...

Swedish population data and concordance for the kits PowerPlexÒ ESX 16 System, PowerPlexÒ ESI 16 System, AmpFlSTRÒ NGMTM, AmpFlSTRÒ SGM PlusTM and Investigator ESSplex

Albinsson, Linda (författare)
Swedish National Laboratory of Forensic Science (SKL), Linköping, Sweden
Norén, Lina (författare)
Swedish National Laboratory of Forensic Science (SKL), Linköping, Sweden
Hedell, Ronny (författare)
Swedish National Laboratory of Forensic Science (SKL), Linköping, Sweden
visa fler...
Ansell, Ricky (författare)
Linköpings universitet,Molekylär genetik,Tekniska högskolan
visa färre...
 (creator_code:org_t)
Clare, Irland : Elsevier, 2011
2011
Engelska.
Ingår i: Forensic Science International. - Clare, Irland : Elsevier. - 1872-4973 .- 1878-0326. ; 5:3, s. e89-e92
  • Tidskriftsartikel (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • The European Standard Set of loci (ESS) has been extended with five additional short tandem repeat (STR) loci following the recommendations of the European Network of Forensic Science Institutes (ENFSI) and the European DNA Profiling Group (EDNAP) to increase the number of loci routinely used by the European forensic community. Subsequently, a new extended Swedish population database, based on 425 individuals, has been assembled using the new STR multiplex kits commercially available.Allele frequencies and statistical parameters of forensic interest for 15 autosomal STR loci (D3S1358, TH01, D21S11, D18S51, D10S1248, D1S1656, D2S1338, D16S539, D22S1045, vWA, D8S1179, FGA, D2S441, D12S391 and D19S433) were obtained from the analysis of the PowerPlex® ESX 16 System kit (Promega Corporation, USA). According to the data no evidence of deviations from Hardy–Weinberg equilibrium was found. The observed heterozygosity varies between 0.755 (TH01) and 0.892 (D1S1656). The power of discrimination was smallest for D22S1045 (0.869) and largest for D1S1656 (0.982) while the power of exclusion was smallest for TH01 (0.518) and largest for D1S1656 (0.778).A concordance study was performed on the five amplification systems: PowerPlex® ESX 16 System, PowerPlex® ESI 16 System (Promega Corporation, USA), AmpFlSTR® NGM™, AmpFlSTR® SGM Plus™ (Applied Biosystems, USA) and Investigator ESSplex (Qiagen, Germany) to reveal null alleles and other divergences between the kits. For the 425 DNA profiles included, AmpFlSTR® NGM™ revealed two null alleles, AmpFlSTR® SGM Plus™ revealed one, and Investigator ESSplex revealed a micro-variant, while the rest of the alleles showed full concordance between the kits tested.

Nyckelord

NATURAL SCIENCES
NATURVETENSKAP

Publikations- och innehållstyp

vet (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy