SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Wronkowska A.A.)
 

Sökning: WFRF:(Wronkowska A.A.) > Optical spectra of ...

Optical spectra of Zn1-xBexTe mixed crystals determined by IR-VIS-UV ellipsometry and photoluminescence measurements

Wronkowska, A A (författare)
University of Technology and Life Science, Bydgoszcz
Arwin, Hans (författare)
Linköpings universitet,Tillämpad optik,Tekniska högskolan
Firszt, F (författare)
Nicholas Copernicus University
visa fler...
Legowski, S (författare)
Nicholas Copernicus University
Wronkowski, A (författare)
University of Technology and Life Science, Bydgoszcz
Skowronski, L (författare)
University of Technology and Life Science, Bydgoszcz
visa färre...
 (creator_code:org_t)
ELSEVIER SCIENCE SA, PO BOX 564, 1001 LAUSANNE, SWITZERLAND, 2011
2011
Engelska.
Ingår i: THIN SOLID FILMS. - : ELSEVIER SCIENCE SA, PO BOX 564, 1001 LAUSANNE, SWITZERLAND. - 0040-6090. ; 519:9, s. 2795-2800
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Spectroscopic ellipsometry in the photon energy range from 0.04 eV to 6.50 eV is used for investigation of the optical response of Zn1-xBxTe crystals grown by a high-pressure Bridgman method in the composition range x andlt;= 0.12. Infrared spectra display absorption bands centred between 411 cm(-1) and 420 cm(-1) associated with BeTe-type optical phonon modes. The positions of the transverse-optical and longitudinal-optical phonon modes have been found by modelling the line shape of the complex dielectric functions, (epsilon) over tilde and Im(-(epsilon) over tilde (-1)), using a classical damped Lorentzian oscillator approach. Ellipsometric measurements in the VIS-UV range allow determination of the fundamental energy-gap (E-0) and the higher threshold energies (E-1, E-1 + Delta(1), E-2) originating from the band edge and spin-orbit splitting critical points. We have found that the Be content x = 0.12 causes an increase of the fundamental energy gap about 0.15 eV at room temperature when compared to the E-0 = 2.23 eV of ZnTe crystal at the same temperature. Photoluminescence spectra were measured in the temperature range from 30 K to room temperature. Luminescence at temperature Tandgt;200 K is very weak. The peak positions of the exciton emission lines agree well with the E-0 band-gaps derived from ellipsometric data if corrected for their temperature dependence.

Nyckelord

ZnBeTe
Ellipsometry
Dielectric function
Lattice vibration
Interband transitions
Photoluminescence
TECHNOLOGY
TEKNIKVETENSKAP

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy