Sökning: L773:1475 0961 >
Determination of ri...
Determination of right ventricular volume and function using multiple axially rotated MRI slices
-
- Aneq Åström, Meriam (författare)
- Östergötlands Läns Landsting,Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken US
-
- Nylander, Eva (författare)
- Östergötlands Läns Landsting,Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken US
-
- Ebbers, Tino (författare)
- Linköpings universitet,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Fysiologi,Hälsouniversitetet,Mekanisk värmeteori och strömningslära
-
visa fler...
-
- Engvall, Jan (författare)
- Östergötlands Läns Landsting,Linköpings universitet,Klinisk fysiologi,Hälsouniversitetet,Fysiologiska kliniken US
-
visa färre...
-
(creator_code:org_t)
- Blackwell Publishing Ltd, 2011
- 2011
- Engelska.
-
Ingår i: Clinical Physiology and Functional Imaging. - : Blackwell Publishing Ltd. - 1475-0961 .- 1475-097X. ; 31:3, s. 233-239
- Relaterad länk:
-
https://liu.diva-por... (primary) (Raw object)
-
visa fler...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Pandgt;Background: The conventional magnetic resonance imaging (MRI) method for right ventricular (RV) volume and motion, using short-axis (SA) orientation, is limited by RV anatomy and shape. We suggest an orientation based on six slices rotated around the long axis of the RV, rotated long axis (RLA). Materials and methods: Three phantoms were investigated in SA and RLA using cine balanced steady-state free precession MRI. Volumes were calculated based on segmentation and checked against true volumes. In 23 healthy male volunteers, we used six long-axis planes from the middle of the tricuspid valve to the RV apex, rotated in 30 degrees increments. For comparison, short-axis slices were acquired. Imaging parameters were identical in both acquisitions. Results: Right ventricular end-diastolic (EDV), end-systolic (ESV) and stroke volumes (SV) determined in the RLA 179 center dot 1 +/- 29 center dot 3; 80 center dot 1 +/- 17 center dot 1; 99 center dot 3 +/- 16 center dot 9 ml and in the SA were 174 center dot 0 +/- 21 center dot 1; 78 center dot 8 +/- 13 center dot 6; 95 center dot 3 +/- 14 center dot 5 ml with P-values for the difference from 0 center dot 17 to 0 center dot 64 (ns). Interobserver variability ranged between 3 center dot 2% and 6 center dot 6% and intraobserver variability between 2 center dot 8% and 6 center dot 8%. In SA views, consensus for the definition of the basal slice was necessary in 39% of the volunteers for whom the average volume change was 20% in ESV and 10% in EDV. Conclusions: The RLA method results in better visualization and definition of the RV inflow, outflow and apex. Accurate measurement of RV volumes for diagnosis and follow-up of cardiac diseases are enhanced by the RLA orientation, even though additional acquisition time is required.
Nyckelord
- axial rotation
- cine MRI
- heart volumes
- methodological comparison
- normal values
- MEDICINE
- MEDICIN
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek
Till lärosätets databas