Sökning: WFRF:(Dizdar Segrell Nil 1960 ) >
A model for simulat...
A model for simulation and patient-specific visualization of the tissue volume of influence during brain microdialysis
-
- Diczfalusy, Elin (författare)
- Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan
-
- Zsigmond, Peter (författare)
- Östergötlands Läns Landsting,Linköpings universitet,Neurokirurgi,Hälsouniversitetet,Neurokirurgiska kliniken US
-
- Dizdar (Dizdar Segrell), Nil, 1960- (författare)
- Östergötlands Läns Landsting,Linköpings universitet,Neurologi,Hälsouniversitetet,Neurologiska kliniken
-
visa fler...
-
- Kullman, Anita (författare)
- Linköpings universitet,Klinisk kemi,Hälsouniversitetet
-
- Loyd, Dan (författare)
- Linköpings universitet,Mekanisk värmeteori och strömningslära,Tekniska högskolan
-
- Wårdell, Karin (författare)
- Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan,MINT
-
visa färre...
-
(creator_code:org_t)
- 2011-11-13
- 2011
- Engelska.
-
Ingår i: Medical and Biological Engineering and Computing. - : Springer Publishing Company. - 0140-0118 .- 1741-0444. ; 49:12, s. 1459-1469
- Relaterad länk:
-
https://liu.diva-por... (primary) (Raw object)
-
visa fler...
-
http://liu.diva-port...
-
https://urn.kb.se/re...
-
https://doi.org/10.1...
-
visa färre...
Abstract
Ämnesord
Stäng
- Microdialysis can be used in parallel to deep brain stimulation (DBS) to relate biochemical changes to the clinical outcome. The aim of the study was to use the finite element method to predict the tissue volume of influence (TVI(max)) and its cross-sectional radius (r (TVImax)) when using brain microdialysis, and visualize the TVI(max) in relation to patient anatomy. An equation based on Fick's law was used to simulate the TVI(max). Factorial design and regression analysis were used to investigate the impact of the diffusion coefficient, tortuosity and loss rate on the r (TVImax). A calf brain tissue experiment was performed to further evaluate these parameters. The model was implemented with pre-(MRI) and post-(CT) operative patient images for simulation of the TVI(max) for four patients undergoing microdialysis in parallel to DBS. Using physiologically relevant parameter values, the r (TVImax) for analytes with a diffusion coefficient D = 7.5 × 10(-6) cm(2)/s was estimated to 0.85 ± 0.25 mm. The simulations showed agreement with experimental data. Due to an implanted gold thread, the catheter positions were visible in the post-operative images. The TVI(max) was visualized for each catheter. The biochemical changes could thereby be related to their anatomical origin, facilitating interpretation of results.
Publikations- och innehållstyp
- ref (ämneskategori)
- art (ämneskategori)
Hitta via bibliotek