SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Geijer Håkan 1961 )
 

Sökning: WFRF:(Geijer Håkan 1961 ) > (2010-2014) > Virtual non-contras...

Virtual non-contrast dual-energy CT compared to single-energy CT of the urinary tract : a prospective study

Lundin, Margareta (författare)
Department of Radiology, Örebro University Hospital, Örebro University, Örebro, Sweden,Department of Radiology, Örebro University Hospital, 701 85 Örebro, Sweden
Liden, Mats, 1976- (författare)
Örebro universitet,Institutionen för hälsovetenskap och medicin,Department of Radiology, Örebro University Hospital, Örebro University, Örebro, Sweden,Department of Radiology, Örebro University Hospital, 701 85 Örebro, Sweden
Magnusson, A, (författare)
Department of Radiology, Örebro University Hospital, 701 85 Örebro, Sweden,Clinical Epidemiology and Biostatistic Unit, Örebro University Hospital, Örebro, Sweden
visa fler...
Abdulilah Mohammed, A. (författare)
Department of Radiology, Örebro University Hospital, 701 85 Örebro, Sweden,Department of Radiology, Linköping University Hospital, Linköping, Sweden
Geijer, Håkan, 1961- (författare)
Örebro universitet,Institutionen för hälsovetenskap och medicin,Department of Radiology, Örebro University Hospital, Örebro University, Örebro, Sweden,Department of Radiology, Örebro University Hospital, 701 85 Örebro, Sweden
Andersson, Torbjörn (författare)
Örebro universitet,Linköpings universitet,Medicinsk radiologi,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Hälsouniversitetet,Institutionen för hälsovetenskap och medicin,Department of Radiology, Örebro University Hospital, Örebro University, Örebro, Sweden
Persson, Anders (författare)
Östergötlands Läns Landsting,Linköpings universitet,Medicinsk radiologi,Centrum för medicinsk bildvetenskap och visualisering, CMIV,Hälsouniversitetet,Röntgenkliniken i Linköping,Center for Medical Image Science and Visualization (CMIV), Linköping University, Linköping, Sweden
visa färre...
 (creator_code:org_t)
2012-07-01
2012
Engelska.
Ingår i: Acta Radiologica. - : Informa Healthcare. - 0284-1851 .- 1600-0455. ; 53:6, s. 689-694
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Background: Dual-energy computed tomography (DECT) has been shown to be useful for subtracting bone or calcium in CT angiography and gives an opportunity to produce a virtual non-contrast-enhanced (VNC) image from a series where contrast agents have been given intravenously. High noise levels and low resolution have previously limited the diagnostic value of the VNC images created with the first generation of DECT. With the recent introduction of a second generation of DECT, there is a possibility of obtaining VNC images with better image quality at hopefully lower radiation dose compared to the previous generation.Purpose: The aim of this study is to compare the image quality of the single-energy series to a VNC series obtained with a two generations of DECT scanners. CT of the urinary tract was used as a model.Material and Methods: Thirty patients referred for evaluation of haematuria were examined with an older system (Somatom Definition) and another 30 patients with a new generation (Somatom Definition Flash). One single-energy series was obtained before and one dual-energy series after administration of intravenous contrast media. We created a VNC series from the contrast-enhanced images. Images were assessed concerning image quality with a visual grading scale evaluation of the VNC series with the single-energy series as gold standard.Results: The image quality of the VNC images was rated inferior to the single-energy variant for both scanners, OR range 11.5-67.3 for the Definition and OR 2.1-2.8 for the Definition Flash. Visual noise and overall quality were regarded as better with Flash than Definition.Conclusions: Image quality of VNC images obtained with the new generation of DECT is still slightly inferior compared to native images. However the difference is smaller with the new compared to the older system.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Radiologi och bildbehandling (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Radiology, Nuclear Medicine and Medical Imaging (hsv//eng)

Nyckelord

Dual-energy computed tomography
image quality
urinary tract imaging
virtual non-enhanced image series
bone-iodine differentiation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy