SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Carlsson Tedgren Åsa)
 

Sökning: WFRF:(Carlsson Tedgren Åsa) > Investigation of si...

Investigation of signal fading in lithium formate EPR dosimeters using a new sensitive method

Adolfsson, Emelie (författare)
Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
Karlsson, Mattias (författare)
Linköpings universitet,Avdelningen för radiologiska vetenskaper,Hälsouniversitetet
Alm Carlsson, Gudrun (författare)
Östergötlands Läns Landsting,Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet,Radiofysikavdelningen US
visa fler...
Carlsson Tedgren, Åsa (författare)
Östergötlands Läns Landsting,Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet,Radiofysikavdelningen US,Swedish Radiation Safety Authority, Stockholm, Sweden
Lund, Eva (författare)
Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
Olsson, Sara (författare)
Central Hospital Växjö, Sweden
Gustafsson, Håkan (författare)
Linköpings universitet,Medicinsk radiofysik,Hälsouniversitetet
visa färre...
 (creator_code:org_t)
2012-03-29
2012
Engelska.
Ingår i: Physics in Medicine and Biology. - : Institute of Physics (IOP). - 0031-9155 .- 1361-6560. ; 57:8, s. 2209-2217
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aim of this study was to investigate signal fading in lithium formate electron paramagnetic resonance (EPR) dosimeters used for clinical applications in radiotherapy. A new experimental method for determination of signal fading, designed to resolve small changes in signal from slowly decaying unstable radicals, was used. Possible signal fading in lithium formate due to different storage temperatures was also tested. Air humidity was kept at a constant level of 33% throughout the experiments. The conclusion drawn from the investigations was that the EPR signal from lithium formate is stable during at least 1 month after irradiation and is not sensitive to variations in storage temperature andlt;40 degrees C when kept at a relative air humidity of 33%. This makes lithium formate a suitable dosimeter for transfer dosimetry in clinical audits.

Nyckelord

MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy