Sonoclot coagulation analysis : A study of test variability

Ekbäck, Gustav (författare)
Department of Anesthesiology and Intensive Care, Örebro Medical Center Hospital, Örebro, Sweden and Department of Statistics, University of Örebro, Örebro, Sweden
Carlsson, Olle (författare)
Department of Anesthesiology and Intensive Care, Örebro Medical Center Hospital, Örebro, Sweden and Department of Statistics, University of Örebro, Örebro, Sweden
Schött, Ulf (författare)
Department of Anesthesiology and Intensive Care, Örebro Medical Center Hospital, Örebro, Sweden and Department of Statistics, University of Örebro, Örebro, Sweden
 (creator_code:org_t)
1999
1999
Engelska.
Ingår i: Journal of Cardiothoracic and Vascular Anesthesia. - 1053-0770 .- 1532-8422. ; 13:4, s. 393-397
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective: To test the reproducibility of Sonoclot coagulation analysis (SCA; Sienco Inc, Morrison, CO). The authors wished to determine if the mix/release of the preloaded celite activator in standard Sono-cuvettes could be responsible for the high variation coefficients for SCA parameters with citrated whole blood and if citrated whole blood is optimal for SCA.Design: A prospective trial.Setting: A large academic teaching medical center.Participants: Eight healthy volunteers.Interventions: Repeated blood sampling was performed through indwelling radial artery catheters. Seven different Sonoclot analyzers were used to test seven different types of analysis procedures in the volunteers, involving activators of different types and amounts and in different forms, and the use of citrated or native whole blood.Measurments and Main Results: Two-way and one-way ANOVA, variance, variance analysis, and Tukey's test were used to evaluate differences in SCA methods and volunteer influence. A high variance, with SDs up to 200% of the median values of the SCA parameters with recalcified citrated blood and the standard Sono-cuvette, was confirmed. SCA with native blood and/or the use of other types of preloaded activators, ie, kaolin, significantly (p < 0.05) reduced this variance. Repeated SCAs further reduced the variance to 10% to 35% of the variance for a single analysis (standard cuvette and native blood).Conclusion: Improvement of the activator in the Sonocuvette, use of native whole blood, and repeated Sonoclot analyses reduced the previously reported high variability of this instrument.

Nyckelord

Sonoclot coagulation analysis
thromboelastography
celite
kaolin
activated coagulation time
platelet function
variance
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Ekbäck, Gustav
Carlsson, Olle
Schött, Ulf
Artiklar i publikationen
Journal of Cardi ...
Av lärosätet
Linköpings universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy