SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:liu-80126"
 

Sökning: id:"swepub:oai:DiVA.org:liu-80126" > Radiation dose opti...

  • Geijer, HåkanDepartment of Radiology, Örebro University Hospital, Örebro, Sweden (författare)

Radiation dose optimization in coronary angiography and percutaneous coronary intervention (PCI) : I. Experimental studies

  • Artikel/kapitelEngelska2002

Förlag, utgivningsår, omfång ...

  • 2002-01-26
  • Springer Science and Business Media LLC,2002
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-80126
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-80126URI
  • https://doi.org/10.1007/s00330-001-1237-6DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • The objectives of this study were to evaluate the influence on image quality and dose to the patient and operator of various equipment settings for percutaneous coronary intervention (PCI), and to optimize the set-up. With an Alderson phantom, different settings, such as projection, protective screens, filtration, image intensifier size and collimation, were evaluated. Kerma-area product (KAP) was recorded as a measure of patient dose and scattered radiation was measured with an ionization chamber. Effective dose for a standardized PCI procedure was measured with thermoluminescent dosimeters inside the phantom. Image quality was evaluated with a contrast-detail phantom. Based on these findings, the equipment set-up was optimized to a low fluoroscopy dose rate with a sufficient image quality. Several operating parameters affected dose, particularly scattered radiation. The optimization reduced the fluoroscopy KAP rate from 44 to 16 mGy cm2/s using 15 cm of acrylic. The effective dose was reduced from 13 to 4.6 mSv for a standardized PCI procedure. Radiation dose to patient and operator in PCI is heavily dependent on both equipment set-up and operating parameters which can be influenced by the operator. With a careful optimization, a large reduction of radiation dose is possible.

Ämnesord och genrebeteckningar

  • MEDICINE
  • MEDICIN

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Beckman, Karl-WilhelmDepartment of Medical Physics, Örebro University Hospital, Örebro, Sweden (författare)
  • Andersson, TorbjörnDepartment of Radiology, Örebro University Hospital, Örebro, Sweden (författare)
  • Persliden, JanDepartment of Medical Physics, Örebro University Hospital, Örebro, Sweden(Swepub:liu)janpe60 (författare)
  • Department of Radiology, Örebro University Hospital, Örebro, SwedenDepartment of Medical Physics, Örebro University Hospital, Örebro, Sweden (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:European Radiology: Springer Science and Business Media LLC12:10, s. 2571-25810938-79941432-1084

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy