SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:2235 3186 OR L773:1660 8151
 

Sökning: L773:2235 3186 OR L773:1660 8151 > Utilization of UV a...

  • Enberg, PerÖstergötlands Läns Landsting,Linköpings universitet,Njurmedicin,Hälsouniversitetet,Njurmedicinska kliniken US (författare)

Utilization of UV absorbance for estimation of phosphate elimination during hemodiafiltration

  • Artikel/kapitelEngelska2012

Förlag, utgivningsår, omfång ...

  • 2012-10-05
  • S. Karger,2012
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:liu-86432
  • https://urn.kb.se/resolve?urn=urn:nbn:se:liu:diva-86432URI
  • https://doi.org/10.1159/000341598DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • funding agencies|Estonian Science Foundation|8621|Estonian targeted financing project|SF0140027s07|European Union through the European Regional Development Fund||Signhild Engkvists Stiftelse, in Stockholm||
  • Background: Phosphate is an important factor in explaining the high progress of vascular calcification among dialysis patients. Today, phosphate concentration is measured in plasma on a regular basis. The aim of this study was to find out if it is possible to estimate total removed phosphate (TRp) in spent dialysate utilizing UV absorbance during hemodiafiltration. Methods: Eleven patients were monitored online with UV absorbance at 297 nm, three times during one week each (n = 33). Dialysate samples were taken at different times during treatment and from a collection tank to chemically determine phosphate concentrations. Two mathematical models (UVIND and UVGROUP) were tested to estimate TRp with supervision by UV absorbance and compared with TRp measured in the tank (reference). Results: High correlation between UV absorbance and phosphate concentration for each single patient and lower for the whole group together was found. TRp was (mean +/- SD) 30.7 +/- 7.3 mmol for the reference and 30.8 +/- 8.2 and 29.1 +/- 5.2 mmol for UVIND and UVGROUP, respectively (p > 0.05). Conclusion: This study demonstrates a novel possibility to estimate TRp based on linear relationship between online monitoring of UV absorbance and concentration of phosphate in spent dialysate.

Ämnesord och genrebeteckningar

  • UV absorbance
  • Hyperphosphatemia
  • Chronic kidney disease
  • Online hemodiafiltration

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Fridolin, IvoTallinn University of Technology, Estonia (författare)
  • Holmar, JanaTallinn University of Technology, Estonia (författare)
  • Fernström, AndersÖstergötlands Läns Landsting,Linköpings universitet,Njurmedicin,Hälsouniversitetet,Njurmedicinska kliniken US(Swepub:liu)andfe39 (författare)
  • Uhlin, FredrikÖstergötlands Läns Landsting,Linköpings universitet,Njurmedicin,Hälsouniversitetet,Njurmedicinska kliniken US(Swepub:liu)freuh89 (författare)
  • Linköpings universitetNjurmedicin (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Nephron. Clinical practice: S. Karger121:1-2, s. c1-c91660-81512235-31861660-2110

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy