SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Fredriksson Ingemar 1980 )
 

Sökning: WFRF:(Fredriksson Ingemar 1980 ) > Experimental result...

Experimental results using a three-layer skin model for diffuse reflectance spectroscopy

Strömberg, Tomas, 1966- (författare)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan,Tomas Strömberg
Karlsson, Hanna, 1981- (författare)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan,Tomas Strömberg
Fredriksson, Ingemar, 1980- (författare)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan,Tomas Strömberg
visa fler...
Larsson, Marcus, 1974- (författare)
Linköpings universitet,Biomedicinsk instrumentteknik,Tekniska högskolan,Tomas Strömberg
visa färre...
 (creator_code:org_t)
SPIE - International Society for Optical Engineering, 2013
2013
Engelska.
Ingår i: Optical Tomography and Spectroscopy of Tissue X. - : SPIE - International Society for Optical Engineering. - 9780819493477 ; , s. 857834-1-857834-8
  • Konferensbidrag (övrigt vetenskapligt/konstnärligt)
Abstract Ämnesord
Stäng  
  • We have previously presented an inverse Monte Carlo algorithm based on a three-layer semi-infinite skin model for analyzing diffuse reflectance spectroscopy (DRS) data. The algorithm includes pre-simulated Monte Carlo data for a range of physiologically relevant epidermal thicknesses and tissue scattering levels. The simulated photon pathlength distributions in each layer are stored and the absorption effect from tissue chromophores added in the post-processing. Recorded DRS spectra at source-detector distances of 0.4 and 1.2 mm were calibrated for the relative intensity between the two distances and matched to simulated spectra in a non-linear optimization algorithm. This study evaluates the DRS spectral fitting accuracy and presents data on the main output parameters; the tissue fraction of red blood cells and local oxygenation (SO2). As a reference, the microcirculatory perfusion (Perf) was measured simultaneously in the same probe using laser Doppler Flowmetry. Data were recorded on the volar forearm of three healthy subjects in a protocol involving a 5 min systolic occlusion. The DRS spectra were modeled with an rms-error < 2%. In two subjects, SO2 decreased during occlusion to <10%, and increased to above baseline after hyperemia, while Perf increased >7 times compared to baseline. In the third subject the SO2 decreased less during occlusion and increased to baseline values at hyperemia with only a 2-fold increase in Perf. The observed difference could be due to different microvascular beds being probed. It is concluded that integrating DRS and LDF enables new possibilities to deduce microcirculation status.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk laboratorie- och mätteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Laboratory and Measurements Technologies (hsv//eng)

Nyckelord

Microcirculation
diffuse reflectance spectra
Monte Carlo simulations
skin modeling
laser Doppler flowmetry

Publikations- och innehållstyp

vet (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy