SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Larsson Åsa)
 

Sökning: WFRF:(Larsson Åsa) > (2010-2014) > A linear programmin...

A linear programming model for optimizing HDR brachytherapy dose distributions with respect to mean dose in the DVH-tail

Holm, Åsa (författare)
Linköpings universitet,Optimeringslära,Tekniska högskolan
Larsson, Torbjörn (författare)
Linköpings universitet,Optimeringslära,Tekniska högskolan
Carlsson Tedgren, Åsa (författare)
Östergötlands Läns Landsting,Linköpings universitet,Avdelningen för radiologiska vetenskaper,Hälsouniversitetet,Radiofysikavdelningen US
 (creator_code:org_t)
2013-07-11
2013
Engelska.
Ingår i: Medical physics (Lancaster). - : American Association of Physicists in Medicine. - 0094-2405. ; 40:8
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Purpose: Recent research has shown that the optimization model hitherto used in high-dose-rate (HDR) brachytherapy corresponds weakly to the dosimetric indices used to evaluate the quality of a dose distribution. Although alternative models that explicitly include such dosimetric indices have been presented, the inclusion of the dosimetric indices explicitly yields intractable models. The purpose of this paper is to develop a model for optimizing dosimetric indices that is easier to solve than those proposed earlier. less thanbrgreater than less thanbrgreater thanMethods: In this paper, the authors present an alternative approach for optimizing dose distributions for HDR brachytherapy where dosimetric indices are taken into account through surrogates based on the conditional value-at-risk concept. This yields a linear optimization model that is easy to solve, and has the advantage that the constraints are easy to interpret and modify to obtain satisfactory dose distributions. less thanbrgreater than less thanbrgreater thanResults: The authors show by experimental comparisons, carried out retrospectively for a set of prostate cancer patients, that their proposed model corresponds well with constraining dosimetric indices. All modifications of the parameters in the authors model yield the expected result. The dose distributions generated are also comparable to those generated by the standard model with respect to the dosimetric indices that are used for evaluating quality. less thanbrgreater than less thanbrgreater thanConclusions: The authors new model is a viable surrogate to optimizing dosimetric indices and quickly and easily yields high quality dose distributions.

Nyckelord

brachytherapy
optimization
treatment planning
dosimetric indices
conditional value-at-risk
MEDICINE
MEDICIN

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy