SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Bolmsvik Åsa 1975 )
 

Sökning: WFRF:(Bolmsvik Åsa 1975 ) > Damping Assessment ...

Damping Assessment of Light Wooden Assembly With and Without Damping Material

Bolmsvik, Åsa, 1975- (författare)
Linnéuniversitetet,Institutionen för bygg- och energiteknik (BE)
Brandt, Anders (författare)
University of Southern Denmark, Denmark
 (creator_code:org_t)
Elsevier BV, 2013
2013
Engelska.
Ingår i: Engineering structures. - : Elsevier BV. - 0141-0296 .- 1873-7323. ; 49, s. 434-447
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Damping elastomers are often used in lightweight wooden constructions and are believed to have good sound insulating effects. In the present study the influence on the structural behaviour by using elastomer damping material (Sylomer®) in the joints, with particular respect to footsteps and floor vibrations, has been investigated. A full scale wooden mock-up was assembled with two different joint configurations and studied under free-free boundary conditions. In the first configuration, the joints between the floor and underlying walls were screwed together. In the second configuration the floor was resting free on top of ribs of elastomer damping material, equivalent to normal building practice when this material is used. Both configurations were analysed and evaluated using experimental modal analysis, in the frequency interval 10-115 Hz. The relative (viscous) damping ratios of the modes were found to be on average 1.2% for the screwed configuration and 2.1% for the configuration with elastomer damping material in the joints. The damping was found to vary significantly between modes in the elastomer case. It was found that at low frequencies damping was high for modes with large motion on the edge where the elastomer material was. At higher frequencies (above approx. 40 Hz), however, the damping for this configuration decreased. This is believed to be caused by a vibration isolation effect of the elastomer, decoupling the floor from the walls at higher frequencies. To assess the differences in vibration levels between the two configurations, mean acceleration levels of well spread points on the different building parts where computed and evaluated. It was found that above approximately 70 Hz, the mean vibration level in the elastomer configuration was significantly lower than for the screwed configuration. Below 70 Hz, however, for many frequencies the mean vibration level for the elastomer configuration was significantly higher than for the screwed configuration (as should be expected in vibration isolation). Problems with springiness and footsteps are due to loads in the frequency range of 10 to 50 Hz, this could indicate that elastomers, used as in the present study, could worsen these types of problems, although improving higher frequency acoustic performance.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Husbyggnad (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Building Technologies (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Strömningsmekanik och akustik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Fluid Mechanics and Acoustics (hsv//eng)

Nyckelord

Elastomer
Sylomer®
Joint
Wooden construction
Damping
Experimental modal analysis
EMA
Footstep
Floor vibration
Springiness
Civil engineering
Byggteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bolmsvik, Åsa, 1 ...
Brandt, Anders
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Samhällsbyggnads ...
och Husbyggnad
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Maskinteknik
och Strömningsmekani ...
Artiklar i publikationen
Engineering stru ...
Av lärosätet
Linnéuniversitetet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy