SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Jonsson Fredrik)
 

Search: WFRF:(Jonsson Fredrik) > A high blood level ...

A high blood level in the venous chamber and a wet-stored dialyzer help to reduce exposure for microemboli during hemodialysis

Ulf, Forsberg (author)
Umeå universitet,Medicin,Umeå university
Jonsson, Per (author)
Umeå universitet,Medicin,Umeå university
Stegmayr, Christofer (author)
Umeå universitet,Medicin,Umeå university
show more...
Jonsson, Fredrik (author)
Umeå universitet,Medicin,Umeå university
Nilsson, Bo (author)
Uppsala universitet,Klinisk immunologi,Uppsala university
Nilsson Ekdahl, Kristina (author)
Uppsala universitet,Klinisk immunologi,Uppsala university,Linnaeus Ctr Biomat Chem, BMC
Stegmayr, Bernd (author)
Umeå universitet,Medicin,Umeå university
show less...
 (creator_code:org_t)
2013-04-29
2013
English.
In: Hemodialysis International. - : Wiley. - 1492-7535 .- 1542-4758. ; 17:4, s. 612-617
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • During hemodialysis (HD), microemboli develop in the blood circuit of the apparatus. These microemboli can pass through the venous chamber and enter into the patient's circulation. The aim of this study was to investigate whether it is possible to reduce the risk for exposure of microemboli by altering of the treatment mode. Twenty patients on chronic HD were randomized to a prospective cross-over study of three modes of HD: (a) a dry-stored dialyzer (F8HPS, Fresenius, steam sterilized) with a low blood level in the venous chamber (DL), (b) the same dialyzer as above, but with a high level in the venous chamber (DH), and (c) a wet-stored dialyzer (Rexeed, Asahi Kasei Medical, gamma sterilized) with a high blood level (WH). Microemboli measurements were obtained in a continuous fashion during 180 minutes of HD for all settings. A greater number of microemboli were detected during dialysis with the setting DL vs. WH (odds ratio [OR] 4.07, 95% confidence interval [CI] 4.03-4.11, P<0.0001) and DH vs. WH (OR 1.18, 95% CI 1.17-1.19, P<0.0001) and less for DH vs. DL (OR 0.290, 95% CI 0.288-0.2930.288-0.293, P<0.0001). These data indicate that emboli exposure was least when using WH, greater with DH, and most with DL. This study shows that using a high blood level in the venous chamber and wet-stored dialyzers may reduce the number of microemboli.CallSend SMSAdd to SkypeYou'll need Skype CreditFree via Skype

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine (hsv//eng)
MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Urologi och njurmedicin (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Urology and Nephrology (hsv//eng)

Keyword

Hemodialysis
microbubbles
microemboli
venous chamber
dialyzer
in vivo
Immunologi
Immunology

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view