SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Jian Guan)
 

Sökning: WFRF:(Jian Guan) > Co-placement optimi...

Co-placement optimization in sensor-reusable cyber-physical digital microfluidic biochips

Li, Jian-De (författare)
Natl Chung Hsing Univ, Taiwan
Kuo, Chun-Hao (författare)
Natl Chiao Tung Univ, Taiwan
Lu, Guan-Ruei (författare)
Natl Chiao Tung Univ, Taiwan
visa fler...
Wang, Sying-Jyan (författare)
Natl Chung Hsing Univ, Taiwan
Li, Katherine Shu-Min (författare)
Natl Sun Yat Sen Univ, Taiwan
Ho, Tsung-Yi (författare)
Natl Tsing Hua Univ, Taiwan
Chen, Hung-Ming (författare)
Natl Chiao Tung Univ, Taiwan
Hu, Shiyan (författare)
Linnéuniversitetet,Institutionen för datavetenskap och medieteknik (DM),CPS
visa färre...
 (creator_code:org_t)
Elsevier, 2019
2019
Engelska.
Ingår i: Microelectronics Journal. - : Elsevier. - 0959-8324 .- 0026-2692. ; 83, s. 185-196
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Digital microfluidic biochips (DMFBs) facilitate modern healthcare applications. One of the most important applications is point-of-care (POC) clinical diagnosis which is directly related to human health. However, biochemical experiments are usually error-prone, which makes monitoring intermediate results during bioassay execution be required to ensure the correctness of POC clinical diagnosis. To tackle this problem, cyber-physical digital microfluidic biochips with integrated sensors have been proposed and have attracted attention recently. In order to fully utilize the sensors for detection, the reusability of sensors should be taken into consideration during the module placement stage of cyber-physical DMFBs synthesis flow. Moreover, excessive actuation of electrodes may cause reliability degradation and this issuse should also be taken care of during module placement stage. In order to deal with the aforementioned problems, this paper presents the first co-optimization method for both module and sensor placement. Experimental results show that the proposed method can effectively minimize bioassay completion time while meeting all constraints from sensors and electrodes.

Ämnesord

NATURVETENSKAP  -- Data- och informationsvetenskap (hsv//swe)
NATURAL SCIENCES  -- Computer and Information Sciences (hsv//eng)

Nyckelord

Digital microfluidic biochips
Cyber-physical sys-tem
Sensor
Placement
Reliability
Computer Science
Datavetenskap

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy