SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:0022 1694 OR L773:1879 2707
 

Sökning: L773:0022 1694 OR L773:1879 2707 > Evaporation compone...

Evaporation components of a boreal forest : variations during the growing season

Grelle, A. (författare)
SLU, Department of Production Ecology, Uppsala
Lundberg, Angela (författare)
Luleå tekniska universitet,Geovetenskap och miljöteknik
Lindroth, A. (författare)
SLU, Department of Production Ecology, Uppsala
visa fler...
Morén, A.-S. (författare)
SLU, Department of Production Ecology, Uppsala
Cienciala, E. (författare)
SLU, Department of Production Ecology, Uppsala
visa färre...
 (creator_code:org_t)
1997
1997
Engelska.
Ingår i: Journal of Hydrology. - 0022-1694 .- 1879-2707. ; 197:1-4, s. 70-87
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • To improve the understanding of interactions between the boreal forest and the climate system as a key issue for global climate change, the water budget of a mixed pine and spruce forest in central Sweden was estimated by measurements of the water flux components and the total evaporation flux during the period 16 May-31 October 1995. Total evaporation was measured using eddy correlation and the components were obtained using measurements of precipitation, throughfall, tree transpiration, and forest floor evaporation. On a daily basis, tree transpiration was the dominant evaporation component during the vegetation period. However, it could be efficiently blocked by a wet canopy associated with large interception evaporation. The accumulated total evaporation was 399 mm, transpiration was 243 mm, forest floor evaporation was 56 mm and interception evaporation was 74 mm. The accumulated sum of interception, transpiration, and floor evaporation was 51 mm larger than the actual measured total evaporation. This difference was mainly attributed to the fact that transpiration was measured in a rather dense 50-year-old stand while total evaporation represented the average conditions of older, roughly 100-year-old stands. To compare eddy-correlation measurements with small-scale measurements of evaporation components, a source area analysis was made to select the flux data that give the best representation of the investigated stand. Especially under stable atmospheric conditions the requirements for surface homogeneity were very high and extreme care had to be taken to be aware of the flux source areas. Canopy water storage was determined by two methods: by the water balance of the canopy, which gave a result of 3.3 mm; and by the so-called minimum method based on plots of throughfall versus precipitation, which gave a much lower value of 1.5 mm. Seasonal interception evaporation constituted 30% of the precipitation.

Ämnesord

NATURVETENSKAP  -- Geovetenskap och miljövetenskap -- Geokemi (hsv//swe)
NATURAL SCIENCES  -- Earth and Related Environmental Sciences -- Geochemistry (hsv//eng)

Nyckelord

Applied Geology
Tillämpad geologi

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy