Sökning: id:"swepub:oai:DiVA.org:ltu-13429" > A catheter tactile ...

  • Eklund, Anders,1965-Umeå universitet,Institutionen för strålningsvetenskaper,Umeå University Hospital, Department of Biomedical Engineering (författare)

A catheter tactile sensor for measuring hardness of soft tissue : measurement in a silicone model and in an in vitro human prostate model

  • Artikel/kapitelEngelska1999

Förlag, utgivningsår, omfång ...

  • 1999
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:ltu-13429
  • https://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-13429URI
  • https://doi.org/10.1007/BF02513357DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-135121URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Upprättat; 1999; 20070529 (andbra)
  • Tissue hardness is related to tissue composition, and this is often changed by disease. It is therefore of interest to measure the hardness in an objective and non-invasive way. A tactile sensor based on a vibrating piezoelectric ceramic element in a feedback loop is described. When the sensor touches an object it produces a frequency shift related to the hardness of the object. The aim of this study was to develop an in vitro hardness measurement method using a catheter type version of the sensor. The method was evaluated in an established silicone tissue model and on human prostate tissue in vitro. A linear relationship was found with a high degree of explanation (R2 = 0.98) between a cone penetration hardness standard (DIN ISO 2137) applied to the silicone model and the corresponding frequency shift. The results from measurements on a human prostate tissue sample, fixed with formalin, showed that the relative hardness measured with the tactile sensor correlated (R = -0.96, p < 0.001, N = 60) with the proposed hardness related to the histological composition of the prostate tissue. The results indicated that hardness of prostate tissue, and maybe hardness of human tissue in general, can be expressed according to the cone penetration standard and that the hardness can be measured with this tactile sensory system. These findings hold the promise of further development of a non-invasive tool for hardness measurement in a clinical situation

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Bergh, AndersUmeå University Hospital, Department of Pathology (författare)
  • Lindahl, Olof (författare)
  • Umeå universitetInstitutionen för strålningsvetenskaper (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Medical and Biological Engineering and Computing37:5, s. 618-6240140-01181741-0444

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Eklund, Anders, ...
Bergh, Anders
Lindahl, Olof
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Annan medicintek ...
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
Artiklar i publikationen
Medical and Biol ...
Av lärosätet
Luleå tekniska universitet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy