SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Gustafsson Hans Åke)
 

Sökning: WFRF:(Gustafsson Hans Åke) > (2015-2019) > Mechanical characte...

Mechanical characterization and modelling of the temperature-dependent impact behaviour of a biocompatible poly(L-lactide)/poly(ε-caprolactone) polymer blend

Gustafsson, Gustaf (författare)
Luleå tekniska universitet,Material- och solidmekanik
Nishida, Masahiro (författare)
Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya, Aichi 466-8555, Japan
Ito, Yoshikata (författare)
Nagoya Institute of Technology, Gokiso-cho, Showa-ku, Nagoya, Aichi 466-8555, Japan
visa fler...
Häggblad, Hans-Åke (författare)
Luleå tekniska universitet,Material- och solidmekanik
Jonsén, Pär (författare)
Luleå tekniska universitet,Material- och solidmekanik
Takayama, Tetsuo (författare)
Yamagata University, 4-3-16 Jonan, Yonezawa, Yamagata 992-8510, Japan
Todo, Mitsugu (författare)
Research Institute for Applied Mechanics, Kyushu University, 6-1 Kasuga-koen, Kasuga, Fukuoka 816-8580, Japan
visa färre...
 (creator_code:org_t)
Elsevier BV, 2015
2015
Engelska.
Ingår i: Journal of The Mechanical Behavior of Biomedical Materials. - : Elsevier BV. - 1751-6161 .- 1878-0180. ; 51, s. 279-290
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Poly(ε-caprolactone) (PCL) is a ductile, bioabsorbable polymer that has been employed as a blend partner for poly(L-lactic acid) (PLLA). An improvement of the material strength and impact resistance of PLLA/PCL polymer blends compared to pure PLLA has been shown previously. To use numerical simulations in the design process of new components composed of the PLLA/PCL blend, a constitutive model for the material has to be established. In this work, a constitutive model for a PLLA/PCL polymer blend is established from the results of compressive tests at high and low strain rates at three different temperatures, including the body temperature. Finite element simulations of the split Hopkinson pressure bar test using the established constitutive model are carried out under the same condition as the experiments. During the experiments, the changes in the diameter and thickness of the specimens are captured by a high-speed video camera. The accuracy of the numerical model is tested by comparing the simulation results, such as the stress, strain, thickness and diameter histories of the specimens, with those measured in the experiments. The numerical model is also validated against an impact test of non-homogenous strains and strain rates. The results of this study provide a validated numerical model for a PLLA/PCL polymer blend at strain rates of up to 1800 s−1 in the temperature range between 22 °C and 50 °C.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Maskinteknik -- Teknisk mekanik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Mechanical Engineering -- Applied Mechanics (hsv//eng)

Nyckelord

Hållfasthetslära
Solid Mechanics

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy