SwePub
Sök i LIBRIS databas

  Extended search

hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) hsv:(Other Medical Engineering)
 

Search: hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) hsv:(Other Medical Engineering) > (1980-1989) > Rhythmical oscillat...

Rhythmical oscillations in rat testicular microcirculation as recorded by laser Doppler flowmetry

Damber, Jan-Erik (author)
Umeå University, Department of Physiology
Lindahl, Olof (author)
Selstam, Gunnar (author)
Umeå University, Department of Physiology
show more...
Tenland, Torsten (author)
Umeå University, Department of Physiology
show less...
 (creator_code:org_t)
Wiley, 1983
1983
English.
In: Acta Physiologica Scandinavica. - : Wiley. - 0001-6772 .- 1365-201X. ; 118:2, s. 117-123
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • We have earlier reported that local testicular blood flow, recorded by laser Doppler flowmetry, shows large oscillations with a frequency of 5-10 min-1. In the present study it is proposed that the recorded oscillations represent mainly local microvascular blood flow variations rather than variations in total testicular blood flow or tissue movements. The reasons for this are: (a) Blood flow simultaneously measured at two separate sites showed oscillations with different frequencies. (b) A local subcapsular injection of room-tempered saline under one probe site eradicated oscillations under that probe but not under another adjacent probe. (c) When the testicular capsule was split open, recordings of blood flow continued to show oscillations. (d) The amplitude of the oscillations was rather large (peak to peak value about 50% of mean flow value). No movements of the testicular surface were seen. A 20 min continuous infusion of 0.4 microgram/min noradrenaline did induce a decrease in plasma testosterone concentration, but did not change the mean blood flow. However, the oscillations nearly completely disappeared during the infusion period. The present study also shows that laser Doppler flowmetry is a versatile method and the rat testis provides a suitable organ in the study of the origin and functional importance of these oscillations

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Annan medicinteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Other Medical Engineering (hsv//eng)

Keyword

Medical Engineering for Healthcare
Medicinsk teknik för hälsovård

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Damber, Jan-Erik
Lindahl, Olof
Selstam, Gunnar
Tenland, Torsten
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Medical Engineer ...
and Other Medical En ...
Articles in the publication
Acta Physiologic ...
By the university
Luleå University of Technology

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view