SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1530 437X OR L773:1558 1748
 

Sökning: L773:1530 437X OR L773:1558 1748 > Calibrating distanc...

Calibrating distance sensors for terrestrial applications without groundtruth information

Alhashimi, Anas, 1978- (författare)
Luleå tekniska universitet,Signaler och system,Luleå University of Technology, Luleå, Sweden,Mobile Robotics and Olfaction Lab
Varagnolo, Damiano (författare)
Luleå tekniska universitet,Signaler och system,Luleå University of Technology, Luleå, Sweden
Gustafsson, Thomas (författare)
Luleå tekniska universitet,Signaler och system,Luleå University of Technology, Luleå, Swede
 (creator_code:org_t)
IEEE, 2017
2017
Engelska.
Ingår i: IEEE Sensors Journal. - : IEEE. - 1530-437X .- 1558-1748. ; 17:12, s. 3698-3709
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • This paper describes a new calibration procedure for distance sensors that does not require independent sources of groundtruth information, i.e., that is not based on comparing the measurements from the uncalibrated sensor against measurements from a precise device assumed as the groundtruth. Alternatively, the procedure assumes that the uncalibrated distance sensor moves in space on a straight line in an environment with fixed targets, so that the intrinsic parameters of the statistical model of the sensor readings are calibrated without requiring tests in controlled environments, but rather in environments where the sensor follows linear movement and objects do not move. The proposed calibration procedure exploits an approximated expectation maximization scheme on top of two ingredients: an heteroscedastic statistical model describing the measurement process, and a simplified dynamical model describing the linear sensor movement. The procedure is designed to be capable of not just estimating the parameters of one generic distance sensor, but rather integrating the most common sensors in robotic applications, such as Lidars, odometers, and sonar rangers and learn the intrinsic parameters of all these sensors simultaneously. Tests in a controlled environment led to a reduction of the mean squared error of the measurements returned by a commercial triangulation Lidar by a factor between 3 and 6, comparable to the efficiency of other state-of-the art groundtruth-based calibration procedures. Adding odometric and ultrasonic information further improved the performance index of the overall distance estimation strategy by a factor of up to 1.2. Tests also show high robustness against violating the linear movements assumption.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Reglerteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Control Engineering (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Nyckelord

expectation maximization
distance sensors
intrinsic sensors calibration
heteroscedastic models
simultaneous sensors calibration
triangulation lidars
ultrasonic sensors
odometry
Reglerteknik
Control Engineering

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy