SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:2352 801X
 

Sökning: L773:2352 801X > (2020) > Estimation of main ...

Estimation of main aquifer parameters using geoelectric measurements to select the suitable wells locations in Bahr Al-Najaf depression, Iraq

Abdulrazzaq, Zaidoon Taha (författare)
Directorate of Space and Communications, Ministry of Science and Technology, Baghdad, 10070, Iraq
Al-Ansari, Nadhir, 1947- (författare)
Luleå tekniska universitet,Geoteknologi
Aziz, Nadia Ahmed (författare)
Directorate of Space and Communications, Ministry of Science and Technology, Baghdad, 10070, Iraq
visa fler...
Agbasi, Okechukwu Ebuka (författare)
Michael Okpara University of Agriculture, Department of Physics, Umudike, Nigeria
Etuk, Sunday Edet (författare)
University of Uyo, Department of Physics, Uyo, Nigeria
visa färre...
 (creator_code:org_t)
Holland : Elsevier, 2020
2020
Engelska.
Ingår i: Groundwater for Sustainable Development. - Holland : Elsevier. - 2352-801X. ; 11
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The aquifer parameters like hydraulic conductivity and transmissivity are extremely important for the management and development of groundwater resources. Vertical Electrical Sounding (VES) and 2D Electrical Resistivity Imaging (ERI) techniques were adopted for geophysical investigation in Fadaq plantation area within Bahr Al-Najaf depression, Iraq. A total of 22 VES point distributed as a grid along six profiles in the plantation with half-current electrode spacing (AB/2) is 400 m are used to evaluate the aquifer geoelectric and hydraulic parameters, where six 2D ERI profiles were conducted and concatenated as one 2D ERI profile with a total length of 4525 m to verify the results of VES. The average formation factor of the aquifer is 22.33 with porosity and water saturation average of 22.62% and 0.59% respectively. Geoelectric and hydraulic parameters estimated values are; apparent resistivity 2.17–2.92 Ω, formation factor 6.23–31.18, porosity 17.91–40.06%, water saturation 0.18–0.85, longitudinal conductance 1.60–10.06 Ω-1, transverse resistance 3258–27200 Ωm2, hydraulic conductivity 0.62–0.68 m2/day and transmissivity 70.68–198.05 m2/day. The thickness and bulk resistivity vary between 112 and 320 m and 18–85 Ωm respectively. About 26% of the aquifer in the study area has an intermediate designation, while 73.91% of the aquifer has high designation. There is a linear relationship between transmissivity and water saturation. Based on designation, protective capacity, and groundwater supply potential VES 6C, VES 7A, VES 4C and VES 2E were recommended for new drilling sites.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Samhällsbyggnadsteknik -- Geoteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Civil Engineering -- Geotechnical Engineering (hsv//eng)

Nyckelord

Aquifers
Fadaq Plantation
VES
2D ERI concatenated profile
Transmissivity
Soil Mechanics
Geoteknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy