SwePub
Sök i LIBRIS databas

  Utökad sökning

id:"swepub:oai:DiVA.org:ltu-8293"
 

Sökning: id:"swepub:oai:DiVA.org:ltu-8293" > A resonator sensor ...

  • Eklund, Anders,1965-Umeå universitet,Institutionen för strålningsvetenskaper,Umeå University Hospital, Department of Biomedical Engineering & Informatics (författare)

A resonator sensor for measurement of intraocular pressure : evaluation in an in vitro pig-eye model

  • Artikel/kapitelEngelska2000

Förlag, utgivningsår, omfång ...

  • 2000-08-11
  • IOP Publishing,2000
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:ltu-8293
  • https://urn.kb.se/resolve?urn=urn:nbn:se:ltu:diva-8293URI
  • https://doi.org/10.1088/0967-3334/21/3/302DOI
  • https://urn.kb.se/resolve?urn=urn:nbn:se:umu:diva-135120URI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:art swepub-publicationtype

Anmärkningar

  • Upprättat; 2000; 20070529 (andbra)
  • Intraocular pressure (IOP) measurement is performed routinely at every eye clinic. High IOP, which can be a sign of glaucoma, can lead to degeneration of the retina and can cause blindness. In this study we developed a resonator sensor for IOP measurement based on an oscillator consisting of a piezoelectric element made of lead zirconate titanate, a flat contact piece of nylon and a feedback circuit. The aim of this study was to evaluate the new sensor's ability to determine lOP in an in vitro pig-eye model. Six eyes from four pigs were removed and fixed in agar. They were then pressurized by a saline column (10-35 cm H2O) through a cannula inserted into the vitreous chamber. The IOP was measured with the resonator sensor applied to cornea. An Alcon applanation pneumatonometer and a standard Viggo-Spectramed pressure sensor connected to the saline column were used as references. The IOP as measured with the resonator sensor correlated well with the pressure elicited by the saline column for individual eyes (r = 0.96-0.99, n = 60) and for all eyes (r = 0.92, n = 360). The correlation between the resonance sensor and the pneumatonometer was r = 0.92 (n = 360). The pneumatonometer also showed a good correlation with the saline column (r = 0.98, n = 360). We conclude that our in vitro pig-eye model made it possible to induce reproducible variation in IOP, and measurement of that pressure with the newly developed resonator sensor gave very promising results for development of a clinically applicable IOP tonometer with unique properties.

Ämnesord och genrebeteckningar

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Bäcklund, TomasUmeå University Hospital, Department of Biomedical Engineering & Informatics (författare)
  • Lindahl, Olof (författare)
  • Umeå universitetInstitutionen för strålningsvetenskaper (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Physiological Measurement: IOP Publishing21:3, s. 355-3670967-33341361-6579

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Eklund, Anders, ...
Bäcklund, Tomas
Lindahl, Olof
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Annan medicintek ...
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
Artiklar i publikationen
Physiological Me ...
Av lärosätet
Luleå tekniska universitet
Umeå universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy