SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1879 2219
 

Sökning: L773:1879 2219 > Comparison of low-c...

Comparison of low-complexity fall detection algorithms for body attached accelerometers

Kangas, Maarit (författare)
Department of Medical Technology, University of Oulu
Konttila, Antti (författare)
Department of Medical Technology, University of Oulu
Lindgren, Per (författare)
Luleå tekniska universitet,EISLAB
visa fler...
Winblad, Ikka (författare)
Department of Medical Technology, University of Oulu
Jämsä, Timo (författare)
Department of Medical Technology, University of Oulu
visa färre...
 (creator_code:org_t)
Elsevier BV, 2008
2008
Engelska.
Ingår i: Gait & Posture. - : Elsevier BV. - 0966-6362 .- 1879-2219. ; 28:3, s. 285-291
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • The elderly population is growing rapidly. Fall related injuries are a central problem for this population. Elderly people desire to live at home, and thus, new technologies, such as automated fall detectors, are needed to support their independence and security. The aim of this study was to evaluate different low-complexity fall detection algorithms, using triaxial accelerometers attached at the waist, wrist, and head. The fall data were obtained from standardized types of intentional falls (forward, backward, and lateral) in three middle-aged subjects. Data from activities of daily living were used as reference. Three different detection algorithms with increasing complexity were investigated using two or more of the following phases of a fall event: beginning of the fall, falling velocity, fall impact, and posture after the fall. The results indicated that fall detection using a triaxial accelerometer worn at the waist or head is efficient, even with quite simple threshold-based algorithms, with a sensitivity of 97-98% and specificity of 100%. The most sensitive acceleration parameters in these algorithms appeared to be the resultant signal with no high-pass filtering, and the calculated vertical acceleration. In this study, the wrist did not appear to be an applicable site for fall detection. Since a head worn device includes limitations concerning usability and acceptance, a waist worn accelerometer, using an algorithm that recognizes the impact and the posture after the fall, might be optimal for fall detection.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Inbäddad systemteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Embedded Systems (hsv//eng)

Nyckelord

Inbyggda system
Embedded System

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.