SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:2198 3844 OR L773:2198 3844
 

Sökning: L773:2198 3844 OR L773:2198 3844 > (2022) > A Subdural Bioelect...

A Subdural Bioelectronic Implant to Record Electrical Activity from the Spinal Cord in Freely Moving Rats

Harland, Bruce (författare)
School of Pharmacy, The University of Auckland, Auckland, 1023 New Zealand
Aqrawe, Zaid (författare)
School of Pharmacy, The University of Auckland, Auckland, 1023 New Zealand
Vomero, Maria (författare)
Department of Microsystems Engineering (IMTEK), BrainLinks‐BrainTools Center, University of Freiburg, Freiburg, 79110 Germany
visa fler...
Boehler, Christian (författare)
Department of Microsystems Engineering (IMTEK), BrainLinks‐BrainTools Center, University of Freiburg, Freiburg, 79110 Germany
Cheah, Ernest (författare)
School of Pharmacy, The University of Auckland, Auckland, 1023 New Zealand
Raos, Brad (författare)
School of Pharmacy, The University of Auckland, Auckland, 1023 New Zealand
Asplund, Maria (författare)
Luleå tekniska universitet,Omvårdnad och medicinsk teknik,Department of Microsystems Engineering (IMTEK), BrainLinks‐BrainTools Center, University of Freiburg, Freiburg, 79110 Germany; Freiburg Institute for Advanced Studies (FRIAS), University of Freiburg, Freiburg, 79110 Germany
O'Carroll, Simon J. (författare)
Department of Anatomy & Medical Imaging, School of Medical Sciences, The University of Auckland, Auckland, 1023 New Zealand
Svirskis, Darren (författare)
School of Pharmacy, The University of Auckland, Auckland, 1023 New Zealand
visa färre...
 (creator_code:org_t)
2022-05-02
2022
Engelska.
Ingår i: Advanced Science. - : John Wiley & Sons. - 2198-3844. ; 9:20
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Bioelectronic devices have found use at the interface with neural tissue to investigate and treat nervous system disorders. Here, the development and characterization of a very thin flexible bioelectronic implant inserted along the thoracic spinal cord in rats directly in contact with and conformable to the dorsal surface of the spinal cord are presented. There is no negative impact on hind-limb functionality nor any change in the volume or shape of the spinal cord. The bioelectronic implant is maintained in rats for a period of 12 weeks. The first subdural recordings of spinal cord activity in freely moving animals are presented; rats are plugged in via a recording cable and allowed to freely behave and move around on a raised platform. Recordings contained multiple distinct voltage waveforms spatially localize to individual electrodes. This device has great potential to monitor electrical signaling in the spinal cord after an injury and in the future, this implant will facilitate the identification of biomarkers in spinal cord injury and recovery, while enabling the delivery of localized electroceutical and chemical treatments.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Medicinska och farmaceutiska grundvetenskaper -- Neurovetenskaper (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Basic Medicine -- Neurosciences (hsv//eng)

Nyckelord

bioelectronic implant
electroceutical
polyimide
spinal cord implant
spinal cord injury
spinal recording
Medical Engineering
Medicinsk teknik

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy