The effect of static bone strain on implant stability of bone remodelling

Halldin, Anders (författare)
Jimbo, Ryo (författare)
Gothenburg University,Göteborgs universitet,Malmö högskola,Odontologiska fakulteten (OD),Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Johansson, Carina B., 1955 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institutionen för odontologi,Institute of Clinical Sciences, Department of Biomaterials,Institute of Odontology
visa fler...
Wennerberg, Ann (författare)
Gothenburg University,Göteborgs universitet,Malmö högskola,Odontologiska fakulteten (OD),Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Jacobsson, Magnus (författare)
Albrektsson, Tomas (författare)
Gothenburg University,Göteborgs universitet,Malmö högskola,Odontologiska fakulteten (OD),Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Hansson, Stig (författare)
visa färre...
 (creator_code:org_t)
Elsevier, 2011
2011
Engelska.
Ingår i: Bone. - : Elsevier. - 8756-3282 .- 1873-2763. ; 49:4, s. 783-789
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Bone remodeling is a process involving both dynamic and static bone strain. Although there exist numerous studies on the effect of dynamic strain on implant stability and bone remodeling, the effect of static strain has yet to be clarified. Hence, for this purpose, the effect of static bone strain on implant stability and bone remodeling was investigated in rabbits. Based on Finite Element (FE) simulation two different test implants, with a diametrical increase of 0.15 mm (group A) and 0.05 mm (group B) creating static strains in the bone of 0.045 and 0.015 respectively, were inserted in the femur (group A) and the proximal tibia metaphysis (groups A and B respectively) of 14 rabbits to observe the biological response. Both groups were compared to control implants, with no diametrical increase (group C), which were placed in the opposite leg. At the time of surgery, the insertion torque (ITQ) was measured to represent the initial stability. The rabbits were euthanized after 24 days and the removal torque (RTQ) was measured to analyze the effect on implant stability and bone remodeling. The mean ITQ value was significantly higher for both groups A and B compared to group C regardless of the bone type. The RTQ value was significantly higher in tibia for groups A and B compared to group C while group A placed in femur presented no significant difference compared to group C. The results suggest that increased static strain in the bone not only creates higher implant stability at the time of insertion, but also generates increased implant stability throughout the observation period.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)
NATURVETENSKAP  -- Biologi (hsv//swe)
NATURAL SCIENCES  -- Biological Sciences (hsv//eng)

Nyckelord

Static bone strain
Removal torque
In vivo experiment
Biomechanical FE simulation
Bone remodeling
Static bone strain; Removal torque; In vivo experiment; Biomechanical FE simulation; Bone remodeling

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Bone (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy