SwePub
Sök i LIBRIS databas

  Utökad sökning

L773:1552 4973 OR L773:1552 4981
 

Sökning: L773:1552 4973 OR L773:1552 4981 > Chemically modified...

Chemically modified poly(2-hydroxyethyl methacrylate) cryogel for the adsorption of heparin.

La Spina, Rita (författare)
Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
Tripisciano, C (författare)
Mecca, T (författare)
visa fler...
Cunsolo, F (författare)
Weber, V (författare)
Mattiasson, Bo (författare)
Lund University,Lunds universitet,Bioteknik,Centrum för tillämpade biovetenskaper,Kemiska institutionen,Institutioner vid LTH,Lunds Tekniska Högskola,Biotechnology,Center for Applied Life Sciences,Department of Chemistry,Departments at LTH,Faculty of Engineering, LTH
visa färre...
 (creator_code:org_t)
2014-01-15
2014
Engelska.
Ingår i: Journal of Biomedical Materials Research. Part B - Applied Biomaterials. - : Wiley. - 1552-4981 .- 1552-4973. ; 102:6, s. 1207-1216
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Various clinical procedures, such as cardiovascular surgery or extracorporeal blood purification, involve systemic anticoagulation using heparin. High concentrations of circulating heparin require neutralization due to possible serious bleeding complications. The intravenous administration of the heparin antagonist protamine sulfate is routinely clinically performed, but is frequently associated with adverse reactions. Therefore, there is a need for a valid and safe alternative to achieve extracorporeal heparin removal from blood or plasma, such as a filter, a matrix, or an adsorbent. Here, we describe the development of a macroporous poly(2-hydroxyethyl methacrylate)-based monolithic cryogel functionalized with l-lysine (pHEMA-lys) and the characterization of its selective heparin adsorption. The maximum binding capacity was quantified in vitro using aqueous and serum solutions under static and dynamic conditions, and fresh human plasma under static conditions. The pHEMA-lys bound 40,500 IU and 32,500 IU heparin/g cryogel at the equilibrium in aqueous solution and 50% serum, respectively. In human plasma spiked with 100 IU/mL of heparin, the binding was still highly efficient (4330 IU/g cryogel after 30 min, i.e., 87% of the initial concentration). The cryogels showed good blood compatibility, as indicated by negligible adsorption of albumin, antithrombin III, and total protein, and may thus be suitable for extracorporeal heparin removal. © 2014 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2014.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Industriell bioteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Industrial Biotechnology (hsv//eng)

Publikations- och innehållstyp

art (ämneskategori)
ref (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
La Spina, Rita
Tripisciano, C
Mecca, T
Cunsolo, F
Weber, V
Mattiasson, Bo
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Industriell biot ...
Artiklar i publikationen
Journal of Biome ...
Av lärosätet
Lunds universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy