SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Adams Judith E)
 

Sökning: WFRF:(Adams Judith E) > (2006-2009) > ROC analysis of dir...

ROC analysis of directly measured mandibular cortical width from panoramic radiogarphs for diagnosis of osteoporosis : the OSTEODENT study

Lindh, Christina (författare)
Malmö högskola,Odontologiska fakulteten (OD)
Karayianni, K (författare)
Horner, K (författare)
visa fler...
Mitsea, A (författare)
Mastoris, M (författare)
Berkas, L (författare)
Jacobs, R (författare)
van der Stelt, P (författare)
Harisson, E (författare)
Adams, Judith (författare)
Pavitt, S (författare)
Devlin, H (författare)
visa färre...
 (creator_code:org_t)
2006
2006
Engelska.
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objectives: To determine the diagnostic validity of the width of the inferior mandibular cortex on dental panoramic radiographs (DPRs), as measured directly by observers, for the diagnosis of osteoporosis in peri- and post-menopausal women. Methods: Volunteer female subjects in the 45 to 70 year age band, recruited from four European centres, underwent dual x-ray energy absorptiometry of the hip and lumbar spine, to provide a gold standard diagnosis of osteoporosis, and a DPR examination. Five observers, all oral radiologists but of different experience, made manual measurements of width of the mandibular lower border cortex below the mental foramina bilaterally. Results: Data of 661 subjects (mean age 54.8y; sd = 6.19y) were available for analysis, with 140 (21.2%) being classified as having osteoporosis. Az values are given below: Osteoporosis at any site Osteoporosis at femoral neck Observer Az (se) 95% CI Az (se) 95% CI 1 0.782 0.748-0.813 0.804 0.771-0.833 2 0.766 0.731-0.799 0.757 0.722-0.791 3 0.756 0.721-0.788 0.790 0.757-0.821 4 0.746 0.711-0.779 0.762 0.727-0.794 5 0.710 0.673-0.744 0.752 0.718-0.785 A diagnostic threshold of 3mm resulted in a sensitivity of 50.7% and a specificity of 80.4% (data for median observer, 2). Mean within-subject variance for the five observers was 0.126mm (sd = 0.355mm). Repeatability is the difference between two measurements made by any pair of observers for the same subject and was expected to be less than 0.983 mm for 95% of pairs of observations. Conclusions: Direct measurement of mandibular cortical width was diagnostically effective in diagnosis of osteoporosis. However, repeatability may be a problem in clinical use. This work was supported by a research and technological development project grant from the European Commission FP5 'Quality of Life and Management of Living Resources' (QLK6-2002-02243).

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy