Bacterial colonisation during regular daily use of a power-driven water flosser and risk for cross-contamination. Can it be prevented?

Bertl, Kristina (författare)
Malmö universitet,Odontologiska fakulteten (OD)
Geissberger, Chiarra (författare)
Univ Bern, Sch Dent Med, Dept Periodontol, Bern, Switzerland.
Zinndorf, David (författare)
Univ Bern, Sch Dent Med, Dept Periodontol, Bern, Switzerland.
visa fler...
Edlund Johansson, Pia (författare)
Malmö universitet,Odontologiska fakulteten (OD)
Al-Shammari, Hatem (författare)
Malmö universitet,Odontologiska fakulteten (OD)
Eick, Sigrun (författare)
Univ Bern, Sch Dent Med, Dept Periodontol, Bern, Switzerland.
Stavropoulos, Andreas (författare)
Malmö universitet,Odontologiska fakulteten (OD)
visa färre...
 (creator_code:org_t)
2021-09-18
2022
Engelska.
Ingår i: Clinical Oral Investigations. - : Springer. - 1432-6981 .- 1436-3771. ; 26, s. 1903-1913
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Objective To assess whether bacterial colonisation in a power-driven water flosser can be prevented. Materials and methods Twenty-four patients undergoing supportive periodontal treatment used 2 power-driven water flossers [Sonicare AirFloss (SAF), AirFloss Ultra (SAFU)] for 12 weeks each as follows: (a) with bottled water (BW); (b) with BW and cleaning the device extra-orally twice per week with chlorhexidine gluconate or (c) essential-oil-based (EO) mouth-rinse; (d) with EO only. Water-jet samples were taken after 6 and 12 weeks with the used nozzle and after exchanging to a brand-new nozzle. After 12 weeks, all devices underwent an intensive cleaning procedure. Samples were analysed by PCR-based method for cariogenic and periodontal pathogens and culture for staphylococci, aerobe gram-negative bacteria, and Candida sp. Results Contamination of SAF/SAFU with Streptococcus mutans was found in > 95% of the samples; periodontal pathogens and aerobe gram-negative bacteria were detected in 19-56% of the samples, while Staphylococcus aureus and Candida sp. were identified only in few samples. Contamination rate was basically unaffected by time-point, device, or way of use. Further, exchanging the nozzle did not prevent transmission of a contaminated water-jet, but the intensive cleaning reduced most of the pathogens significantly, except of S. mutans. Conclusion Neither a specific way of use nor exchanging the nozzle prevented bacterial colonisation and transmission of biofilm components via the water-jet of SAF/SAFU.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Nyckelord

AirFloss
Bacterial colonisation
Cross-contamination
Disinfection
Interdental cleaning device
Streptococcus mutans

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy