SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Stavropoulos Andreas)
 

Sökning: WFRF:(Stavropoulos Andreas) > Does implantoplasty...

Does implantoplasty affect the failure strength of narrow and regular diameter implants? : A laboratory study

Bertl, Kristina (författare)
Malmö universitet,Odontologiska fakulteten (OD)
Isidor, Flemming (författare)
Section of Prosthetic Dentistry, Department of Dentistry, Aarhus University
Vult von Steyern, Per (författare)
Malmö universitet,Odontologiska fakulteten (OD)
visa fler...
Stavropoulos, Andreas (författare)
Malmö universitet,Odontologiska fakulteten (OD)
visa färre...
 (creator_code:org_t)
2020-09-07
2021
Engelska.
Ingår i: Clinical Oral Investigations. - : Springer. - 1432-6981 .- 1436-3771. ; 25, s. 2203-2211
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • ObjectiveTo assess whether the impact of implantoplasty (IP) on the maximum implant failure strength depends on implant type/design, diameter, or material.MethodsFourteen implants each of different type/design [bone (BL) and tissue level (TL)], diameter [narrow (3.3 mm) and regular (4.1 mm)], and material [titanium grade IV (Ti) and titanium-zirconium alloy (TiZr)] of one company were used. Half of the implants were subjected to IP in a computerized torn. All implants were subjected to dynamic loading prior to loading until failure to simulate regular mastication. Multiple linear regression analyses were performed with maximum implant failure strength as dependent variable and IP, implant type/design, diameter, and material as predictors.ResultsImplants subjected to IP and TL implants showed statistically significant reduced implant failure strength irrespective of the diameter compared with implants without IP and BL implants, respectively. Implant material had a significant impact for TL implants and for regular diameter implants, with TiZr being stronger than Ti. During dynamic loading, 1 narrow Ti TL implant without IP, 4 narrow Ti TL implants subjected to IP, and 1 narrow TiZr TL implant subjected to IP were fractured.ConclusionIP significantly reduced the maximum implant failure strength, irrespective implant type/design, diameter, or mate- rial, but the maximum implant failure strength of regular diameter implants and of narrow BL implants remained high.Clinical RelevanceIP seems to have no clinically relevant impact on the majority of cases, except from those of single narrow Ti TL implants, which may have an increased risk for mechanical complications. This should be considered for peri-implantitis treatment planning (e.g., communication of potential complications to the patient), but also in the planning of implant installation (e.g., choosing TiZr instead of Ti for narrow implants).

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Bertl, Kristina
Isidor, Flemming
Vult von Steyern ...
Stavropoulos, An ...
Om ämnet
MEDICIN OCH HÄLSOVETENSKAP
MEDICIN OCH HÄLS ...
och Klinisk medicin
och Odontologi
Artiklar i publikationen
Clinical Oral In ...
Av lärosätet
Malmö universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy