SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Willman Ania)
 

Sökning: WFRF:(Willman Ania) > Performing Subcutan...

  • Annersten, MagdalenaÖresund Diabetes Team AB, Lund, Sweden (författare)

Performing Subcutaneous Injections : a literature review

  • Artikel/kapitelEngelska2005

Förlag, utgivningsår, omfång ...

  • Alpha Beta Sigma,2005
  • electronicrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:mau-835
  • https://urn.kb.se/resolve?urn=urn:nbn:se:mau:diva-835URI
  • https://doi.org/10.1111/j.1741-6787.2005.00030.xDOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:vet swepub-contenttype
  • Ämneskategori:for swepub-publicationtype

Anmärkningar

  • Background: Persons using daily subcutaneous injections to administer medicine perform them in different ways and thereby increase the risk of skin complications related to the injection. It is often part of nurses’ role to administer medicine and educate the patient in injection technique. Course literature in nursing education, commercial patient education pamphlets, and instructional leaflets do not give consistent advice regarding subcutaneous injection technique. Aim: The aim of this review was to identify the scientific foundation for the technical performance of subcutaneous injections. The question to be answered was: How should a subcutaneous injection be administered to achieve the right dose in the right place with minimum complications? Method: The review included a search in three databases, a screening process at abstract level, followed by a quality assessment of included articles. The quality assessment was done independently by two people and followed specific protocols. Result: A total of 38 articles were assessed for quality and covered information on dose, location, and complications of subcutaneous injection. The assessed studies are heterogeneous in design and describe different aspects of the subcutaneous injection technique. Therefore, the scientific foundation for technical performance is weak. However, several studies indicate that the amount of subcutaneous fat and appropriate needle length are of high importance for the drug to reach the target tissue. Conclusion: More research regarding effective subcutaneous injection technique needs to be done.

Ämnesord och genrebeteckningar

  • administration of medication
  • diabetes
  • heparin
  • injection technique
  • insulin
  • insulin pen
  • lipohypertrophy
  • needles
  • subcutaneous injection
  • literature review
  • syringe

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Willman, AniaMalmö högskola,Institutionen för vårdvetenskap (VV)(Swepub:mau)hsanwi (författare)
  • Öresund Diabetes Team AB, Lund, SwedenInstitutionen för vårdvetenskap (VV) (creator_code:org_t)

Sammanhörande titlar

  • Ingår i:Worldviews on Evidence-Based Nursing: Alpha Beta Sigma2:3, s. 122-1301545-102X1741-6787

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Annersten, Magda ...
Willman, Ania
Artiklar i publikationen
Worldviews on Ev ...
Av lärosätet
Malmö universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy