SwePub
Sök i LIBRIS databas

  Utökad sökning

hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) hsv:(Medical Materials)
 

Sökning: hsv:(ENGINEERING AND TECHNOLOGY) hsv:(Medical Engineering) hsv:(Medical Materials) > (2020-2024) > Comparing the Effec...

Comparing the Effectiveness of EMG and Electrical Impedance myography Measurements for Controlling Prosthetics

Abdullah, Saad (författare)
Mälardalens universitet,Inbyggda system
Hafid, Abdelakram (författare)
Mälardalens universitet,Inbyggda system
Shahid, H. (författare)
Coventry University, Research Centre for Intelligent Healthcare, Coventry, United Kingdom
 (creator_code:org_t)
Institute of Electrical and Electronics Engineers Inc. 2023
2023
Engelska.
Ingår i: IEEE Int. Multidiscip. Conf. Eng. Technol., IMCET. - : Institute of Electrical and Electronics Engineers Inc.. - 9798350313826 ; , s. 189-193
  • Konferensbidrag (refereegranskat)
Abstract Ämnesord
Stäng  
  • In recent years, the field of prosthetics has made significant progress towards creating prosthetic devices that are more functional, comfortable, and user-friendly. However, achieving intuitive control over prosthetic hand movements remains a significant challenge, especially for individuals with limb loss who rely on prosthetics for independent daily activities. To address this challenge, researchers have explored the potential of non-invasive techniques as electromyography (EMG) for prosthetic control. This paper aims to investigate the potential of using EMG and the electrical impedance myography (EIMG) techniques jointly for the measurement of hand movements. The study involved recording and comparing EMG and EIMG signals from a cohort of healthy individuals. These signals were captured during four distinct hand gestures: opening and closing the hand, as well as extending and flexing it, under varying time conditions, allowing for categorization into low and high-intensity movements. Data collection employed the Open BCI and ZRPI devices. The analysis of these signal waveforms revealed compelling results. Brachioradialis activity in EMG 2 exhibited an increase during open hand (0.015mV) and extension hand (0.009mV in low and 0.013mV in high intensity) gestures, accompanied by increased EIMG activity (56mV and 52mV respectively). Additionally, close hand (0.0018mV in low and 0.05mV in high intensity) and flexion hand (0.0075 in low intensity and 0.002 in high intensity) gestures exhibited heightened flexor carpi ulnaris activity with raised EIMG activity (57mV and 45mV respectively). These results proved to be consistent, acceptable, and aligned with existing literature. The findings of this paper indicate that both EMG and EIMG techniques could be used together to control custom-made hand prosthetics, demonstrating a significant development that could lead to more intuitive and easier-to-control prosthetics. Also, the results obtained could be valuable to researchers and engineers working in the prosthetics field, as it provides insights into the potential of non-invasive techniques for prosthetic control.

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Medicinteknik -- Medicinsk material- och protesteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Medical Engineering -- Medical Materials (hsv//eng)

Nyckelord

Biomedical application
Electrical Impedance Myography
Electromyography
Prosthetic
Electric impedance
Electric impedance measurement
Prosthetics
Signal analysis
Biomedical applications
Electrical impedance
Hands movement
High intensity
Low-intensity
Noninvasive technique
Prosthetic controls
Prosthetic devices
User friendly
Medical applications

Publikations- och innehållstyp

ref (ämneskategori)
kon (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
Abdullah, Saad
Hafid, Abdelakra ...
Shahid, H.
Om ämnet
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Medicinteknik
och Medicinsk materi ...
Artiklar i publikationen
IEEE Int. Multid ...
Av lärosätet
Mälardalens universitet

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy