Reference setup for characterization and calibration of low-range differential pressure sensors

Nazar Ul Islam, Muhammad (author)
Mittuniversitetet,Avdelningen för elektronikkonstruktion
Oelmann, Bengt, Professor (thesis advisor)
Mittuniversitetet,Avdelningen för elektronikkonstruktion
Cheng, Peng, Doktor (thesis advisor)
Mittuniversitetet,Avdelningen för elektronikkonstruktion
 (creator_code:org_t)
ISBN 9789188025098
Sundsvall : Mittuniversitetet, 2015
English 67 s.
Series: Mid Sweden University licentiate thesis, 1652-8948 ; 115
  • Licentiate thesis (other academic/artistic)
Abstract Subject headings
Close  
  • In this thesis, a reference setup for the characterization and calibration of low range differential pressure sensors is presented. The setup utilizes the principle of ideal gas law and actuates on the volume for accurate reference pressure inputs for the calibration process. The error sources for the proposed setup are analysed and an error propagation modelis presented. The range of the setup is ±320 Pa, with the resolution of 0.001% of full scale. The verified sensitivity of the setup is 0.032 Pa. A complete characterization of a high performance differential pressure transducer is conducted as a test case study for the performance analysis of the proposed setup. During these experiments the sensitivity of the calibration setup to the thermal gradient is observed. To this end, the effects of thermal gradient on the transient response of the setup are also studied, utilizing a comparative experimental study. From the presented experimental study it is concluded that the thermal gradient can cause the system to remain in transient state for at least 96 hours. To reduce this effect, a mechanical design optimization is proposed and a finite element model is presented to be studied in comparison to its preceding design for its thermal performance. From the results it is concluded that the optimized design can reduce the transient time of the measurement system due to thermal gradient, by 11 times. Future work is also proposed to further investigate the optimized model for implementation purposes.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Publication and Content Type

vet (subject category)
lic (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Nazar Ul Islam, ...
Oelmann, Bengt, ...
Cheng, Peng, Dok ...
About the subject
ENGINEERING AND TECHNOLOGY
ENGINEERING AND ...
and Electrical Engin ...
Parts in the series
Mid Sweden Unive ...
By the university
Mid Sweden University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view