SwePub
Sök i LIBRIS databas

  Utökad sökning

(WFRF:(Pfeiffer Andreas))
 

Sökning: (WFRF:(Pfeiffer Andreas)) > X-ray deconvolution...

X-ray deconvolution microscopy

Ehn, Sebastian (författare)
Tech Univ Munich, Phys Dept, Lehrstuhl Biomed Phys, James Franck Str, D-85748 Garching, Germany
Epple, Franz Michael (författare)
Tech Univ Munich, Phys Dept, Lehrstuhl Biomed Phys, James Franck Str, D-85748 Garching, Germany
Fehringer, Andreas (författare)
Tech Univ Munich, Phys Dept, Lehrstuhl Biomed Phys, James Franck Str, D-85748 Garching, Germany
visa fler...
Pennicard, David (författare)
Deutsch Elektronen Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany
Graafsma, Heinz (författare)
Mittuniversitetet,Avdelningen för elektronikkonstruktion,Deutsch Elektronen Synchrotron DESY, Notkestr 85, D-22607 Hamburg, Germany
Noel, Peter (författare)
Tech Univ Munich, Phys Dept, Lehrstuhl Biomed Phys, James Franck Str, D-85748 Garching, Germany
Pfeiffer, Franz (författare)
Tech Univ Munich, Phys Dept, Lehrstuhl Biomed Phys, James Franck Str, D-85748 Garching, Germany
visa färre...
 (creator_code:org_t)
2016
2016
Engelska.
Ingår i: Biomedical Optics Express. - 2156-7085. ; 7:4, s. 1227-1239
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Recent advances in single-photon-counting detectors are enabling the development of novel approaches to reach micrometer-scale resolution in x-ray imaging. One example of such a technology are the MEDIPIX3RX-based detectors, such as the LAMBDA which can be operated with a small pixel size in combination with real-time on-chip charge-sharing correction. This characteristic results in a close to ideal, box-like point spread function which we made use of in this study. The proposed method is based on raster-scanning the sample with sub-pixel sized steps in front of the detector. Subsequently, a deconvolution algorithm is employed to compensate for blurring introduced by the overlap of pixels with a well defined point spread function during the raster-scanning. The presented approach utilizes standard laboratory x-ray equipment while we report resolutions close to 10 mu m. The achieved resolution is shown to follow the relationship p/n with the pixel-size p of the detector and the number of raster-scanning steps n. (C) 2016 Optical Society of America

Ämnesord

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)
NATURVETENSKAP  -- Fysik -- Acceleratorfysik och instrumentering (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences -- Accelerator Physics and Instrumentation (hsv//eng)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy