SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Thungström Göran)
 

Sökning: WFRF:(Thungström Göran) > Signal-to-Noise Rat...

Signal-to-Noise Ratio Optimization in X-ray Fluorescence Spectrometry for Chromium Contamination Analysis

An, Siwen (författare)
Mittuniversitetet,Institutionen för elektronikkonstruktion,Radiation Sensor Systems,Mittuniversitet
Reza, Salim, 1985- (författare)
Högskolan i Gävle,Elektronik
Norlin, Börje, 1967- (författare)
Mittuniversitetet,Institutionen för elektronikkonstruktion,Mittuniversitet
visa fler...
Fröjdh, Christer, 1952- (författare)
Mittuniversitetet,Institutionen för elektronikkonstruktion,Mittuniversitet
Thungström, Göran, 1960- (författare)
Mittuniversitetet,Institutionen för elektronikkonstruktion,Mittuniversitet
visa färre...
 (creator_code:org_t)
Elsevier BV, 2021
2021
Engelska.
Ingår i: Talanta. - : Elsevier BV. - 0039-9140 .- 1873-3573. ; 230
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • In most cases, direct X-ray fluorescence (XRF) analysis of solutions entails technical difficulties due to a high X-ray scattering background resulting in a spectrum with a poor signal-to-noise ratio (SNR). Key factors that determine the sensitivity of the method are the energy resolution of the detector and the amount of scattered radiation in the energy range of interest. Limiting the width of the primary spectrum by the use of secondary targets, or filters, can greatly improve the sensitivity for specific portions of the spectrum. This paper demonstrates a potential method for SNR optimization in direct XRF analysis of chromium (Cr) contamination. The suggested method requires minimal sample preparation and achieves higher sensitivity compared to existing direct XRF analysis. Two states of samples, fly ash and leachate from municipal solid waste incineration, were investigated. The effects of filter material, its absorption edge and filter thickness were analyzed using the combination of Monte Carlo N-Particle (MCNP) code and energy-dispersive XRF spectrometry. The applied filter removes primary photons with energies interfering with fluorescence photons from the element of interest, thus results in lower background scattering in the spectrum. The SNR of Cr peak increases with filter thickness and reaches a saturation value when further increased thickness only increases the measurement time. Measurements and simulations show that a Cu filter with a thickness between 100 μm and 140 μm is optimal for detecting Cr by taking into account both the SNR and the exposure time. With direct XRF analysis for solutions, the limit of quantitation (LOQ) of the achieved system was 0.32 mg/L for Cr, which is well below the allowed standard limitation for landfills in Sweden. This work shows that XRF can gain enough sensitivity for direct monitoring to certify that the Cr content in leachate is below environmental limits.

Ämnesord

NATURVETENSKAP  -- Kemi -- Analytisk kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences -- Analytical Chemistry (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Naturresursteknik -- Miljöledning (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Environmental Engineering -- Environmental Management (hsv//eng)
NATURVETENSKAP  -- Fysik (hsv//swe)
NATURAL SCIENCES  -- Physical Sciences (hsv//eng)
NATURVETENSKAP  -- Kemi (hsv//swe)
NATURAL SCIENCES  -- Chemical Sciences (hsv//eng)

Nyckelord

Chromium
Environmental monitoring
Hazardous materials
Limit of quantitation (LOQ)
Waste management
X-ray fluorescence analysis (XRF)

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

  • Talanta (Sök värdpublikationen i LIBRIS)

Till lärosätets databas

Hitta mer i SwePub

Av författaren/redakt...
An, Siwen
Reza, Salim, 198 ...
Norlin, Börje, 1 ...
Fröjdh, Christer ...
Thungström, Göra ...
Om ämnet
NATURVETENSKAP
NATURVETENSKAP
och Kemi
och Analytisk kemi
TEKNIK OCH TEKNOLOGIER
TEKNIK OCH TEKNO ...
och Naturresurstekni ...
och Miljöledning
NATURVETENSKAP
NATURVETENSKAP
och Fysik
NATURVETENSKAP
NATURVETENSKAP
och Kemi
Artiklar i publikationen
Talanta
Av lärosätet
Mittuniversitetet
Högskolan i Gävle

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy