SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Artale G.)
 

Sökning: WFRF:(Artale G.) > An experimental cha...

  • Rinaldi, S. (författare)

An experimental characterization of time of arrival accuracy for time synchronization of medium voltage smart grid solutions

  • Artikel/kapitelEngelska2019

Förlag, utgivningsår, omfång ...

  • Institute of Electrical and Electronics Engineers Inc.2019
  • printrdacarrier

Nummerbeteckningar

  • LIBRIS-ID:oai:DiVA.org:miun-41385
  • https://urn.kb.se/resolve?urn=urn:nbn:se:miun:diva-41385URI
  • https://doi.org/10.1109/AMPS.2019.8897769DOI

Kompletterande språkuppgifter

  • Språk:engelska
  • Sammanfattning på:engelska

Ingår i deldatabas

Klassifikation

  • Ämneskategori:ref swepub-contenttype
  • Ämneskategori:kon swepub-publicationtype

Anmärkningar

  • Cited By :1; Export Date: 4 March 2021; Conference Paper
  • The time synchronization of smart grid devices is a critical feature for the successful application of advanced grid monitoring and control techniques. Synchronization mechanisms based on the accurate estimation of the Time of Arrival (ToA) of network messages-sent over power line cables-are a promising solution to achieve synchronization tasks over distribution lines. In this paper, a chirp-based synchronization technique over the Medium Voltage (MV) grid has been proposed and characterized. Such approach has the benefit of not requiring the installation of a dedicated infrastructure, thanks to the exploitation of power distribution lines for the transmission of time synchronization data. The effectiveness of the approach has been experimentally evaluated on a simplified MV line available in a testing laboratory. Although, the tested chirp has a limited frequency bandwidth (80 kHz), the maximum variation of the ToA estimation is on the order of 3.5 μs, which fulfills the requirements of most smart grid applications. © 2019 IEEE.

Ämnesord och genrebeteckningar

  • Chirp modulation
  • Medium Voltage Distribution Grid
  • Performance Evaluation
  • Smart Grid
  • Time of Arrival
  • Time Synchronization
  • Electric power system measurement
  • Electric power transmission networks
  • Frequency estimation
  • Laboratories
  • Smart power grids
  • Synchronization
  • Experimental characterization
  • Medium voltage
  • Power distribution lines
  • Synchronization mechanisms
  • Synchronization technique

Biuppslag (personer, institutioner, konferenser, titlar ...)

  • Di Cara, D. (författare)
  • Panzavecchia, N. (författare)
  • Tine, G. (författare)
  • Bonafini, F. (författare)
  • Ferrari, P. (författare)
  • Flammini, A. (författare)
  • Pasetti, M. (författare)
  • Sisinni, E. (författare)
  • Artale, G. (författare)
  • Cataliotti, A. (författare)
  • Cosentino, V. (författare)

Sammanhörande titlar

  • Ingår i:AMPS 2019 Proceedings: Institute of Electrical and Electronics Engineers Inc.9781728100753

Internetlänk

Hitta via bibliotek

Till lärosätets databas

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy