SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(Mattsson Hans)
 

Search: WFRF:(Mattsson Hans) > Design of a Microma...

Design of a Micromachined Thermopile Infrared Sensor with a Self-Supported SiO2/SU-8 Membrane

Mattsson, Claes, 1978- (author)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013),Electronics design division, STC
Thungström, Göran (author)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013),Electronics design division
Bertilsson, Kent (author)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013),Electronics design division
show more...
Nilsson, Hans-Erik (author)
Mittuniversitetet,Institutionen för informationsteknologi och medier (-2013),Electronics design division
Martin, Hans (author)
SenseAir AB
show less...
 (creator_code:org_t)
Piscataway, USA : IEEE, 2008
2008
English.
In: IEEE Sensors Journal. - Piscataway, USA : IEEE. - 1530-437X .- 1558-1748. ; 8:12, s. 2044-2052
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • In the infrared region of the spectrum thermoelectric detectors such as the thermopile, are extensively used. These detectors rely on the well-known Seebeck effect, in which there is a direct conversion of thermoelectric differentials into electrical voltage. The temperature difference over thermocouple junctions is in general, created by forming a thin membrane connected to the silicon bulk. In many existing thermopiles, materials such as Si and Si3N4 have been used as membrane. These materials suffer from relatively high thermal conductivity, which lowers the membrane temperature and reduces the sensitivity of the detector. A material such as SU-8 2002 has a much lower thermal conductivity and is applied using standard photolithographic processing steps. This work presents thermal simulations regarding the use of SU-8 2002 as a thermal insulating membrane as compared to Si and Si3N4. The simulation results presented show that the temperature increase in a 5 µm SiO2/SU-8 membrane is about 9% higher than in a 1 µm Si3N4 membrane, despite the membrane thickness being increased by a factor of 5. A thermopile consisting of 196 serially interconnected Ti/Ni thermocouples positioned on a 5 µm SiO2/SU-8 2002 membrane has been fabricated. The sensitivity of the fabricated device has been evaluated in the infrared region, using a 1.56 µm IR laser and a xenon arc lamp together with a monochromator. The measurement results show a sensitivity of approximately 5 V/W over the wavelength range between 900 - 2200 nm. Measurements performed in a vacuum chamber show that the sensitivity of the detector could be increased by more than a factor of 3 by mounting the detector in a vacuum sealed capsule.

Subject headings

TEKNIK OCH TEKNOLOGIER  -- Elektroteknik och elektronik -- Annan elektroteknik och elektronik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Electrical Engineering, Electronic Engineering, Information Engineering -- Other Electrical Engineering, Electronic Engineering, Information Engineering (hsv//eng)

Keyword

Infrared sensor
self-supported membrane
SU-8
thermopile
Electronics
Elektronik

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view