SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Rask Eva 1958 )
 

Sökning: WFRF:(Rask Eva 1958 ) > Reliability of the ...

Reliability of the DSS-Swe Questionnaire

Jans, Anders, 1981- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,Department of Surgery, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
Rask, Eva, 1958- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,University Health Care Research Centre
Ottosson, Johan, 1957- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Surgery
visa fler...
Magnuson, Anders (författare)
Clinical Epidemiology and Biostatistics, School of Medical Sciences, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
Szabo, Eva, PhD, 1973- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Surgery
Stenberg, Erik, 1979- (författare)
Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department of Surgery
visa färre...
 (creator_code:org_t)
Springer, 2023
2023
Engelska.
Ingår i: Obesity Surgery. - : Springer. - 0960-8923 .- 1708-0428. ; 33:11, s. 3487-3493
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • BACKGROUND: Symptomatic postbariatric hypoglycemia (PBH) is a known complication that can occur a few years after Roux-en-Y gastric bypass (RYGB). There is currently no established rating scale for PBH-associated symptoms developed for use in Swedish populations. The aim of the study was to translate an already existing questionnaire into Swedish and to test its reliability.METHODS: The study included forward and backward translations of the original Dumping Severity Scale (DSS) questionnaire with 8 items regarding symptoms of early dumping and 6 items regarding hypoglycemia, with each item graded on a 4-point Likert scale. The reliability of the Swedish translated questionnaire (DSS-Swe) was estimated using internal consistency and test-retest methods.RESULTS: A total of 200 patients were included in the study. Good internal consistency was demonstrated regarding the items related to early dumping symptoms, with a Cronbach's alpha coefficient of 0.82, and very good agreement in terms of test-retest reliability, with an overall intraclass correlation coefficient (ICC) of 0.91 (95% CI 0.88-0.93). The items related to hypoglycemia yielded a good Cronbach's alpha coefficient of 0.76 and an ICC of 0.89 (95% CI 0.85-0.91).CONCLUSION: The DSS-Swe questionnaire shows good reliability regarding both internal consistency and test-retest performance for use in Swedish populations.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Kirurgi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Surgery (hsv//eng)

Nyckelord

Bariatric surgery
Hypoglycemia
Questionnaire
Reliability test
Translation

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy