SwePub
Sök i LIBRIS databas

  Extended search

WFRF:(van Nieuwenhoven Michiel)
 

Search: WFRF:(van Nieuwenhoven Michiel) > Rectal Sensory and ...

Rectal Sensory and Compliance Testing : A Method Comparison Study between High-Resolution Anorectal Manometry and Barostat Investigations

Marinica Grando, Lucian, 1982- (author)
Örebro universitet,Institutionen för medicinska vetenskaper,Department Gastroenterology, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
Halfvarson, Jonas, 1970- (author)
Örebro universitet,Institutionen för medicinska vetenskaper,Department Gastroenterology, Faculty of Medicine and Health, Örebro University, Örebro, Sweden
van Nieuwenhoven, Michiel A, 1965- (author)
Örebro universitet,Institutionen för medicinska vetenskaper,Region Örebro län,Department Gastroenterology
 (creator_code:org_t)
MDPI, 2024
2024
English.
In: Diagnostics. - : MDPI. - 2075-4418. ; 14:4
  • Journal article (peer-reviewed)
Abstract Subject headings
Close  
  • Abnormal visceral perception and motor function are often observed in patients with fecal incontinence, evacuation disorders and irritable bowel syndrome. The international anorectal physiology working group has proposed a standardization for anorectal function assessment, where rectal sensitivity testing is performed using an elastic balloon attached to a high-resolution anorectal manometry (HRAM) catheter. Rectal compliance, another component of rectal function evaluation, is a pressure-volume relationship that refers to the rectum's ability to stretch and expand as it receives and holds fecal matter. There are no data available regarding the possibility of compliance testing using HRAM, although this is theoretically possible by correcting for the elastic balloon's intrinsic properties. The gold standard for measurement of visceral sensitivity and compliance is the rectal barostat, according to the procedure described by the European COST action GENIEUR group. Data on the agreement between the two different procedures are scarce. Hence, we performed a comparative study of the HRAM and barostat investigations in 26 healthy individuals. We hypothesized that by inflating the balloon before the examination, rectal compliance can be measured with HRAM investigations, and we examined correlations and levels of agreement between the methods. Our results demonstrate that assessing rectal compliance with HRAM is technically possible; however, a strong correlation with the rectal barostat was only observed at the maximum tolerable volume (Spearman's rho = 0.7, p = 0.02). We only found moderate correlations (Spearman's rho = 0.562, p = 0.019) for compliance according to the barostat methodology and for rectal sensibility testing (Spearman's rho = 0.57, p = 0.03 for maximum tolerable volume). Bland-Altman plots showed poor levels of agreement between the methods. We conclude that HRAM and the rectal barostat cannot be used interchangeably for compliance or sensitivity assessments. We suggest the development of a non-elastic balloon with a fixed size and shape to assess rectal sensory function and compliance in HRAM testing.

Subject headings

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Gastroenterologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Gastroenterology and Hepatology (hsv//eng)

Keyword

High-resolution anorectal manometry
rectal barostat
rectal compliance
rectal sensory function

Publication and Content Type

ref (subject category)
art (subject category)

Find in a library

To the university's database

Find more in SwePub

By the author/editor
Marinica Grando, ...
Halfvarson, Jona ...
van Nieuwenhoven ...
About the subject
MEDICAL AND HEALTH SCIENCES
MEDICAL AND HEAL ...
and Clinical Medicin ...
and Gastroenterology ...
Articles in the publication
Diagnostics
By the university
Örebro University

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view