SwePub
Sök i LIBRIS databas

  Extended search

onr:"swepub:oai:DiVA.org:oru-13258"
 

Search: onr:"swepub:oai:DiVA.org:oru-13258" > Uncertainty assessm...

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist
  • Martinez, K. (author)

Uncertainty assessment of polychlorinated dibenzo-p-dioxins and dibenzofuran and dioxin-like polychlorinated biphenyl analysis in stationary source sample emissions in accordance with the impending European standard EN-1948 using fly ashes

  • Article/chapterEnglish2009

Publisher, publication year, extent ...

  • Elsevier BV,2009
  • printrdacarrier

Numbers

  • LIBRIS-ID:oai:DiVA.org:oru-13258
  • https://urn.kb.se/resolve?urn=urn:nbn:se:oru:diva-13258URI
  • https://doi.org/10.1016/j.chroma.2009.06.024DOI

Supplementary language notes

  • Language:English
  • Summary in:English

Part of subdatabase

Classification

  • Subject category:ref swepub-contenttype
  • Subject category:art swepub-publicationtype

Notes

  • The analysis of polychlorinated dibenzo-p-dioxins and dibenzofurans (PCDD/Fs) and dioxin-like polychlorinated biphenyls (dl-PCBs) present in stack gas emissions and solid residues from incinerators will be mandatory in the foreseeable future. European standard EN-1948 is in the process of being updated through the addition of a new Part 4 related to the analysis of the 12 dl-PCBs. Therefore, either a comprehensive and reliable method capable of analyzing all of these 29 compounds (12 dl-PCBs and 17 2,3,7,8-PCDD/Fs) needs to be developed, or the existing PCDD/F analytical procedure must be adapted to include the dl-PCBs. This study has taken the latter approach of modifying PCDD/F methodology and in particular the fractionation step, by isolating dioxins and dl-PCBs into separate fractions ready for high resolution gas chromatography coupled to high resolution mass spectrometry (HRGC/HRMS) analysis. Results obtained from the analysis of Certified Reference Materials (CRM-490 and CRM-615) and fly ashes from the European Committee for Standardization (CEN) intercalibration study demonstrated that the proposed methodology is appropriate to determine the dl-PCBs in accordance with the impending European standard EN-1948. Uncertainty values obtained during the validation of the analytical methodology were 13% total I-TEQ (international Toxic Equivalent) for PCDD/Fs and 31% total WHO-TEQ (World Health Organization Toxic Equivalent) in the case of dl-PCBs. In addition, 'real' samples such as emissions and fly ashes were successfully analyzed following the proposed analytical method. (C) 2009 Elsevier B.V. All rights reserved.

Subject headings and genre

Added entries (persons, corporate bodies, meetings, titles ...)

  • Rivera-Austrui, J. (author)
  • Adrados, M. A. (author)
  • Abalos, M. (author)
  • Llerena, J. J. (author)
  • van Bavel, BertÖrebro universitet,Akademin för naturvetenskap och teknik(Swepub:oru)bvl (author)
  • Rivera, J. (author)
  • Abad, E. (author)
  • Örebro universitetAkademin för naturvetenskap och teknik (creator_code:org_t)

Related titles

  • In:Journal of Chromatography A: Elsevier BV1216:31, s. 5888-58940021-96731873-3778

Internet link

Find in a library

To the university's database

  • 1 of 1
  • Previous record
  • Next record
  •    To hitlist

Search outside SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Close

Copy and save the link in order to return to this view