SwePub
Sök i LIBRIS databas

  Utökad sökning

WFRF:(Sul Young Taeg 1960)
 

Sökning: WFRF:(Sul Young Taeg 1960) > (2010-2014) > The effect of calci...

The effect of calcium ion concentration on the bone response to oxidized titanium implants

Kang, Byung-Soo (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Sul, Young-Taeg, 1960 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
Johansson, Carina B., 1955- (författare)
Örebro universitet,Institutionen för hälsovetenskap och medicin,Department of Clinical Medicine, School of Health and Medical Sciences, Örebro University, Sweden
visa fler...
Oh, Se-Jung (författare)
Department of Physics and Astronomy, Seoul National University, Seoul, South Korea
Lee, Hyun-Ju (författare)
National Center for Inter-University Research Facility, Seoul National University, Seoul, South Korea
Albrektsson, Tomas, 1945 (författare)
Gothenburg University,Göteborgs universitet,Institutionen för kliniska vetenskaper, Avdelningen för biomaterialvetenskap,Institute of Clinical Sciences, Department of Biomaterials
visa färre...
 (creator_code:org_t)
2011-03-28
2012
Engelska.
Ingår i: Clinical Oral Implants Research. - Malden, USA : Wiley-Blackwell. - 0905-7161 .- 1600-0501. ; 23:6, s. 690-697
  • Tidskriftsartikel (refereegranskat)
Abstract Ämnesord
Stäng  
  • Aim: To investigate the effect of calcium concentration on the bone tissue response to Ca-incorporated titanium implants.Materials and methods: Two titanium surfaces containing 4.2% and 6.6% calcium were prepared using the micro-arc oxidation process. The implants were inserted in the tibia of nine New Zealand White rabbits. After 6 weeks of healing, the bone response to the implants was quantitatively compared by biomechanical and histomorphometrical measurements.Results: Ca 4.2% and Ca 6.6% containing implants revealed no distinctive differences in their qualitative surface chemistry; chemical bonding state of Ca in titanium oxide was mainly calcium titanates. No significant differences were observed between two implants in peak removal torque and shear strength comparisons (P>0.05). Histomorphometrical analyses presented no significant differences in bonemetal contact, bone area and newly formed bone measurements between two implants (P>0.05).Conclusions: From biomechanical and histomorphometrical measurements, the two calcium concentrations in this study did not differ significantly with respect to their influence on the bone tissue response. This similar bone response in rabbit tibiae may be explained by the similarity of the qualitative Ca chemistry in titanium surfaces.

Ämnesord

MEDICIN OCH HÄLSOVETENSKAP  -- Klinisk medicin -- Odontologi (hsv//swe)
MEDICAL AND HEALTH SCIENCES  -- Clinical Medicine -- Dentistry (hsv//eng)
TEKNIK OCH TEKNOLOGIER  -- Materialteknik -- Bearbetnings-, yt- och fogningsteknik (hsv//swe)
ENGINEERING AND TECHNOLOGY  -- Materials Engineering -- Manufacturing, Surface and Joining Technology (hsv//eng)

Nyckelord

Bone response
calcium concentration
micro-arc oxidation
shear strength
surface chemistry
titanium implant
Medicine
Medicin
bone response;calcium concentration;micro-arc oxidation;shear strength;surface chemistry;titanium implant

Publikations- och innehållstyp

ref (ämneskategori)
art (ämneskategori)

Hitta via bibliotek

Till lärosätets databas

Sök utanför SwePub

Kungliga biblioteket hanterar dina personuppgifter i enlighet med EU:s dataskyddsförordning (2018), GDPR. Läs mer om hur det funkar här.
Så här hanterar KB dina uppgifter vid användning av denna tjänst.

 
pil uppåt Stäng

Kopiera och spara länken för att återkomma till aktuell vy